7 MAINTENANCE
PAGE
7.1
7.2 Lubrication
The NEMO
®
pump does not require frequent lubrication.
■ Maintenance of the drive should be carried out according to the drive manufacturers
instructions.
Maintenance
If you are not aware of any manufacturer's instructions and there are normal
conditions of use, every 5,000 operating hours, at the latest after every 2 years:
■ Strip down the drive unit.
■ Remove the bearings.
■ Clean all parts.
■ Renew the lubricant.
Special lubricants are often specified for mechanically controlled variable speed
drives.
It is therefore important to follow the drive manufacturers maintenance instructions.
Pump model with “mechanical seals” (sectional drawing W251.000):
The lubricating should be done:
▲ when putting into operation
▲ after every 350 hours of operation
▲ before and after operation interruptions of 6 - 8 weeks
issued: 24.10.2017 Revision: 7
text no.
07202-1/1
copy to: