USER MANUAL
height is entered as a percentage of the Cut Height. The torch remains at this height until
the Jump Time Delay has elapsed. If this feature is not used, clear the Enabled checkbox.
Setting: 50% – 450% of Cut Height
Jump Time
Description: This value sets the number of seconds to hold the torch at the Puddle Jump Height
before transitioning to the Cut Height. This time is used to allow the torch to clear the top dross
puddle that forms during a pierce. If this feature is not used, clear the Enabled checkbox.
Setting: 0 – 10 seconds
AVC Delay
Description: This value sets the number of seconds that are required for the cutting machine and
plasma torch to achieve steady-state operation at the cut height. After this delay, the
AVC is enabled for the remainder of the cut. If the THC is in Sample Voltage mode and Hold
signal is removed, the arc voltage sample is taken after this delay.
Setting: 0 – 10 seconds
Partial Retract
Description: Set this checkbox to select Partial Retract of the torch at the end of a cut.
Retract Height
Description: This parameter specifies height above the workpiece to which the torch retracts at
the end of a cut.
Setting: from 0 mm – to the maximum lifter length
Messages
Show Errors: set this checkbox to show messages to operator about issued errors in the
popup window.
Note: also, all errors are stored in the log box in the diagnostic tabs.
Inform the operator if diff. between Real and Target on cutting start more than:
plugin on the each cutting cycle check the difference between real arc voltage on the start of
the cutting and target arc voltage. If the difference is bigger than this parameter – plugin
inform about this using warning sign in the Set Arc Voltage DRO. It’s helps to operator to
correct target arc voltage depend from state of the consumables or when plate thickness was
changed. Default value is 5 volts.