Page #31 background imageLoading...
Page #31 background image
USER MANUAL
Manual Speed
Description: Manual speed is the speed at which the positioner moves when the control is in the
manual mode. Note that in Manual, the positioner moves at a IHS speed when the up/down
buttons are initially pressed. The speed is increased to the manual speed if the buttons are held
down.
IHS Speed
Description: This parameter sets the slow speed for the final approach to the workpiece during an
IHS operation. It is also used as the slow speed for manual moves.
Acceleration
Description: This acceleration is used for all automatic, manual and IHS moves. This value
depends on the motor parameters, the weight of the lifter load and the desired speed of
operation.
AVC Acceleration
Description: This acceleration is used for moves during arc voltage close-loop operation. This
value depends on the motor parameters, the weight of the lifter load and the desired speed of
operation. Typically, this value is equal to the Acceleration.
Slide Length
Description: This value is the length of the lifter’s usable travel (Soft Limit function).
Safe Jog Height
Description: This value is the length of the lifter’s travel in % from Home position, when torch will
be move on the Manual speed. The rest of the slide length, torch will be move at the IHS speed.
Clear Plate Distance
Description: This value is the distance where system expects the Ohmic or Float head clear plate
signal in IHS procedure.
Settings: 0 20 mm
Pooling period
Description: This value is the time constant of the plugin main loop.
Setting: 15 63 msec recommend value is 15 msec
Input Signal Debouncing
Description: This value is the time constant of the input signals filter.
Setting: 5 63 msec recommend value is 5 msec
Dead Band
Description: This value is an interval of an arc voltage where no AVC occurs.
Setting: 0.25 3.0 V.
Push and Jog mode
This allow to enable advanced jog mode. The lifter initially jogs on 0.25 mm. After 0.5 second,
it begins continuous motion at the IHS Speed. After 2 seconds, the lifter increases the speed to
the programmed Manual Speed.
Uncheck this check box for using regular Jog mode.
Reverse Engine
Description: Set this checkbox to reverse torch move direction.