EU DECLARATION OF CONFORMITY
1. Product model: MSPF-SH-A-7
2. Name and address of the manufacturer or his authorised representative:
MAGICSHOOT
Reigerstraat 110
2025 XG Haarlem
The Netherlands
www.magicshoot.nl
3. This declaration of conformity is issued under the sole responsibility of the manufacturer (or
installer).
4. Object of the declaration:
Equipment:
Powercable; International Extension Cord 16 A / 230VAC; constructed with: 7 meter Titanex H07RN-F
3G1,5mm
2
black cable and two connectors: Neutrik powerCON TRUE1 NAC3FX-W KERAF 621 Schuko.
Brand name: MagicShoot Cable
Model/type: MSPF-SH-A-7
5. The object of the declaration described above is in conformity with the relevant Union
harmonisation legislation:
Low Voltage Directive (LVD) 2014/35/EU,
Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU,
Directive 2008/98/EC on waste (Waste Framework Directive)
6. References to the relevant harmonised standards used or references to the other technical
specifications in relation to which conformity is declared:
LVD: NEN 3140+A1
RoHS: EN 50581:2012
7. Signed for and on behalf of:
Manufacturer: MagicShoot (phone: +31 6 21220846 email: info@magicshoot.nl)
Place and date: Haarlem, 16-02-2017
Sitan van Sluis, Managing Director

Other manuals for NEUTRIK NAC3FX-W

Question and Answer IconNeed help?

Do you have a question about the NEUTRIK NAC3FX-W and is the answer not in the manual?

Summary

EU Declaration of Conformity

Product and Manufacturer Identification

Details the product model, brand name, and manufacturer's contact information.

Object of Declaration and Conformity

Specifies the declared equipment and lists relevant Union harmonisation legislation.

Harmonised Standards Referenced

Lists the harmonised standards used to declare conformity for LVD and RoHS.

Product Specifications and Part Numbering

Technical Cable Details

Lists plug termination, conductor size, cable type, length, and class.

Part Numbering System Explained

Details the system for numbering cable variants based on Neutrik part numbering.

Schucko KERAF Connector Details

Type 621 Specifications

Describes the Schucko KERAF type 621 rubber contactstop, its colour, weight, and features.

User Manual: Operation and Assembly

Operating Instructions

Instructions on how to push and rotate Neutrik connectors for locking and unlocking.

Connector Assignment and Approvals

Details connector assignments (inlet/outlet) and relevant VDE/UL approvals.

Assembly Instructions

Cable Preparation Steps

Guides for inserting cable into bushing/housing, separating parts, and preparing cable.

Assembly Approval Standards

References VDE and UL standards for cable preparation during assembly.

Assembly, Disassembly, and Safety

Wiring and Clamping Procedure

Details on sliding cable into contacts, clamping with screws, and torque values.

Chuck, Housing, and O-ring Assembly

Instructions for assembling chuck, housing, and using O-ring for IP protection.

Disassembly and Safety Warnings

Procedure for disassembling connectors and important safety/caution notes.

Testing Procedures

Test Standards and Methods

Cable tested per NEN3140, including visual inspection and electrical measurements.

Electrical Test Parameters

Specifies resistance values for protective layer/conductor and max leaking current.

Overview

This document describes an International Extension Cord, specifically a power cable designed for 230VAC / 16A applications. It is identified by the model number MSPF-SH-A-7 and is manufactured by MagicShoot. The cable is constructed with a 7-meter black Titanex H07RN-F 3G1,5mm² cable and features two connectors: a Neutrik powerCON TRUE1 NAC3FX-W and a KERAF 621 Schuko plug.

Function Description

The International Extension Cord serves as a power cable, facilitating the connection of electrical appliances to a power source or linking two pieces of equipment. It is designed to supply power at 230VAC and handle a current of up to 16A. The cable's construction, utilizing a robust Titanex H07RN-F cable, ensures durability and reliability for various applications. The inclusion of Neutrik powerCON TRUE1 connectors and a Schuko plug allows for secure and standardized connections in environments where these connector types are prevalent. The powerCON TRUE1 system is certified for breaking capacity according to IEC 60320 and VDE 0625, making it suitable for use as appliance couplers and interconnection couplers. This system is intended to supply power to an appliance and from one appliance to another, ensuring a safe and reliable power transfer.

Usage Features

The extension cord is designed for ease of use and secure connections. To connect the Neutrik connector, users should push and rotate the NAC3MX-W connector into a corresponding contra connector or chassis part until it locks securely. Disconnection is achieved by pushing the yellow button and rotating the connector until it unlocks, then pulling it out. This twist-lock mechanism ensures that the connection remains stable during operation, preventing accidental disconnections. The Schuko plug, a common standard in many European countries, provides a familiar and widely compatible interface for power outlets. The cable is intended for installation by qualified personnel only, emphasizing the importance of proper handling and setup to ensure safety and optimal performance. The design incorporates a strain relief mechanism to protect the cable from bending forces at the connection points, enhancing its longevity.

Maintenance Features

Maintenance of the extension cord primarily involves visual inspection and electrical testing to ensure continued safety and functionality. According to NEN3140 standards, the cable should undergo regular visual inspections to check for any signs of damage, wear, or degradation of the cable jacket and connectors. This includes looking for cuts, abrasions, cracks, or any deformation that could compromise the cable's integrity.

In addition to visual checks, electrical values of the cable should be measured using appropriate testing equipment, such as a Nieaf-Smitt EasyPat 250V NEN3140 apparaattester. Key electrical parameters to be tested include the resistance of the protective layer, which should be at least 1 MΩ, and the resistance of the protective conductor, which should not exceed 0.3 Ω. The maximum leakage current should also be checked and must not exceed 1mA. These electrical tests are crucial for verifying the insulation integrity and the effectiveness of the protective earthing, which are vital for user safety.

For the Neutrik connectors, the assembly instructions highlight specific steps for proper installation and disassembly, which are important for maintaining the connector's integrity and IP protection. During assembly, it is recommended to apply cable pulling lubricant to the cable jacket to facilitate insertion into the bushing and housing. The cable clamp should be tightened with a specific tool to ensure a secure grip and maintain IP protection. A yellow O-ring is used to hide and achieve IP protection, and its proper placement is essential.

In terms of repair or replacement, the safety warning explicitly states that for safety and certification reasons, the connector must be replaced if any parts are broken or show serious damage. This prevents attempts at makeshift repairs that could compromise the device's safety features. The document also mentions the use of cable end bushes and a Knipex crimping tool (97 53 04) for assembly, suggesting that specific tools and components are required for proper maintenance and repair, further emphasizing the need for qualified personnel to handle these tasks. Adherence to these maintenance guidelines ensures the continued safe and reliable operation of the International Extension Cord.

NEUTRIK NAC3FX-W Specifications

General IconGeneral
TypePower Connector
GenderFemale
Poles3
Rated Current16 A
Rated Voltage250 V
Rated Voltage AC250 V
Connector SeriesPowerCON
ColorBlack
Cable O.D.6 - 12 mm
Locking DeviceLocking
FlammabilityUL94 V-0
Temperature Range-30 °C to +80 °C
Contact PlatingSilver
Cable EntryStraight
Mounting TypePanel Mount
Number of Pins3
Operating Temperature-30 °C to +80 °C
Wire Size2.5 mm²
Housing MaterialPolyamide
Shell MaterialPolyamide
TerminationScrew-type terminals