Slide bushing ( 1 ) and chuck ( 2) onto the cable end.
If cable O.D.:
Less 15 mm please use reduction piece (3).
Prepare cable as shown.
Consider excessive length of PE conductor for
slackening.
Strip the wires.
Caution:
The conductor cross section for the rated current is
2
6 mm (10 AWG). In the exceptional case that the
conductor cross section area is smaller as the rated
cross section the maximum current load carrying
capacity has to be assessed according to the limit of
the conductor. Also it is advised to use wire end
sleeves for smaller cross section areas.
A
B
A
[0.354"]
9 mm
FEATURES
250 Vac, 32 Amp (at ambient temperatures up to 35°C) / 30 Amp for cUR
·
Cable O.D. 17 mm (general range: 8.0 to 20.0 mm)
·
2
Wiring: Cable Connector: Screw-type terminals for stranded wires 6.0 mm (AWG 10)
·
2
Chassis Connector: Screw-type terminals for wires 6.0 mm (AWG 10)
IMPORTANT SAFETY INSTRUCTION
Caution: Connector without breaking capacity acc. IEC 61984 - must not be engaged or
disengaged when under load or live.
Attention: Ne pas utiliser pour couper le courant.
Insert wires into terminals L, N, PE and tighten.
ATTENTION: Max torque 130 Ncm
Wiring (left):
C
SAFETY & ASSEMBLY INSTRUCTION
powerCON HC Locking 2P+PE AC appliance coupler
®
|
25 mm 15 mm
[0.985”] [0.590”]
R
1. ASSEMBLY INSTRUCTIONS Cable Connector
I
1.
2.
3.
Page 1BDA 178 V4
C
Torx screw: T10
Max. Torque 130 Ncm
1.
2.
L
Black
N
White
Green
PE
L
Brown
N
Blue
Yellow/Green
PE
Conductor colors according to color coding
of North American cords or rest of the world.
Question and Answer IconNeed help?

Do you have a question about the NEUTRIK PowerCON HC and is the answer not in the manual?

Summary

Important Safety Instructions

Assembly Instructions: Cable Connector

Prepare Cable End

Slide bushing and chuck onto cable end, use reduction piece if needed.

Prepare Cable Conductors

Prepare cable, ensuring sufficient PE conductor length for slackening.

Strip Wires

Strip the required length of wires for termination.

Wire Termination and Torque

Insert wires into terminals (L, PE) and tighten to max torque 130 Ncm.

Assembly Instructions: Receptacle

Prepare Receptacle Wiring

Strip wires and insert them into terminals, tighten securely.

Panel Cutout Dimensions

Details on the required panel cutout size for rear mounting.

NEUTRIK PowerCON HC Specifications

General IconGeneral
TypePower Connector
SeriesPowerCON
SubseriesHC
Voltage Rating250 V
Contact MaterialCopper alloy
Locking DeviceYes
FlammabilityUL 94 V-0
Temperature Range-30 °C to +80 °C
IP RatingIP20
GenderMale or Female
Contact Resistance< 5 mΩ
Insulation Resistance> 100 MΩ
Dielectric Strength4 kV AC
Contact PlatingSilver
Cable O.D.8 - 12 mm
Locking MechanismTwist Lock
Mating Cycles> 1000