Slide bushing and chuck onto cable end, use reduction piece if needed.
Prepare cable, ensuring sufficient PE conductor length for slackening.
Strip the required length of wires for termination.
Insert wires into terminals (L, PE) and tighten to max torque 130 Ncm.
Strip wires and insert them into terminals, tighten securely.
Details on the required panel cutout size for rear mounting.
| Type | Power Connector |
|---|---|
| Series | PowerCON |
| Subseries | HC |
| Voltage Rating | 250 V |
| Contact Material | Copper alloy |
| Locking Device | Yes |
| Flammability | UL 94 V-0 |
| Temperature Range | -30 °C to +80 °C |
| IP Rating | IP20 |
| Gender | Male or Female |
| Contact Resistance | < 5 mΩ |
| Insulation Resistance | > 100 MΩ |
| Dielectric Strength | 4 kV AC |
| Contact Plating | Silver |
| Cable O.D. | 8 - 12 mm |
| Locking Mechanism | Twist Lock |
| Mating Cycles | > 1000 |