SECTION 2 – CONTROLS, INSTRUMENTS AND OPERATION
2–112
Calibration of the Multifunction handle
To calibrate the multifunction handle, proceed as
follows:
1. Select the ”Multifunction handle” calibration
window.
Message: “Refer to manual before continuing”.
Message: “Then press enter”.
2. During this calibration, you will be asked to put the
multifunction handle forward & backward. To
avoid unexpected movement from the machine,
disengage engine & set gear to neutral”.
3. Press ”enter” to continue or ”esc” to abort the
calibration.
190
Message: “Calibration initiated”.
Message: “Calibration Started”.
Message: “Move handle completely forward”.
Message: “Then press enter”.
4. Place the multifunction handle in the most
forward position and press ”enter”.
191
Message: ”Move handle to neutral/ rear position”.
Message: “Then press enter”.
5. Place the multifunction handle in the most
neutral/ rear position and press ”enter”.
192