Load Software Update
TROUBLESHOOTING SCREENS
These e
r
r
or screens will display a service phone number to call if entered in “Setup” Menu (Page 15)
*Usuall
y
repairing a bad connection or replacing the indicated moto
r
will remed
y
the problem.
minutes
Hysteresis cycle
Display Reads Possible Cause(s) Remedies Notes
Fill Timeout Error
Water shut off to Machine Check Water Supply Shutoff
Initial fill time longer than 8
Supply Line Blocked or too small Repair or Replace as needed Fill time Longer than 1 Minute
Water Filter Restricted Replace-Service Required
Water Probe has a 30 second
Inlet Solenoid valve Faulty Replace-Service Required
Control Board Failure Replace-Service Required
Thermistor Error Thermistor not plugged in Make sure plug in housing is latched Open or Shorted Thermistor
Faulty Thermistor Replacement
Control Board Failure Replace-Service Required
Heater Error Faulty Thermistor Replacement 4 Minute Continuous Heater Run
Faulty Heater Element Replace-Service Required
Control Board Failure Replace-Service Required
MotorErrors*
Wiring Disconnected- Pumps Check Pump Motor Wires, Harness
Future updates to the Touch Screen Software will be delivered