17
ERROR MESSAGES
Message - "THERMISTOR ERROR"
THERMISTOR IS OPEN OR SHORTED-REPLACE
PN 151677
Message - "HIGH TEMP ERROR"
RAPID TEMPERATURE RISE-HEATER ON WITH LOW
WATER LEVEL-CHECK FILL VALVE OR WATER SUPPLY
LINE
Message - "UPPER/LOWER MOTOR ERROR"
BREW CHAMBER DRIVE MOTOR ERROR-CHECK FOR
JAM OR OBSTRUCTION IN BREW CHAMBER
Message - "BOARD ERROR"
CONTROL BOARD WRITE ERROR-REPLACE BOARD IF
MESSAGE DOES NOT CLEAR PN 780602
Message - "FILL TIMEOUT ERROR"
WATER NOT REACHING LEVEL PROBE-CHECK WATER
SUPPLY OR CHECK FOR WATER LEAK
Message - "HEATER TIMEOUT ERROR"
WATER NOT HEATED DURING TIMEOUT PERIOD-CHECK
HEATER RELAY PN 110958 OR HEATING ELEMENT PN
704166-10(1700W US) OR 704161-10 (1400W CANADA) OR
HI-LIMIT THERMOSTAT PN 111593