May be due toDescriptionAlarm text on the displayAlarm
Open circuit or short circuit on sensor
input
Sensor does not work (see section "Dis-
turbances in comfort")
Defective control board in AMS 10
Sensor fault, suction gas in AMS 10 (Tho-
S).
Sensor fault Tho-S280
Open circuit or short circuit on sensor
input
Sensor does not work (see section "Dis-
turbances in comfort")
Defective control board in AMS 10
Fault in the refrigerant circuit
Sensor fault, low pressure transmitter in
AMS 10.
Sensor fault LPT281
Outdoor module and indoor module
(VVM) / control module (SMO) are not
compatible.
Heat pump and indoor module (VVM) /
control module (SMO) do not work properly
together due to technical parameters.
Non-compatible outdoor
air heat pump
294
NIBE AMS 10Chapter 9 | Alarm list36