EasyManua.ls Logo

Nibe AMS 10-8 - Energy Labelling

Nibe AMS 10-8
64 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Energy labelling
INFORMATION SHEET
NIBESupplier
AMS 10-16 / HBS 05-
16
AMS 10-12 / HBS 05-
12
AMS 10-8 / HBS 05-
12
AMS 10-6 / HBS 05-6Model
35 / 5535 / 5535 / 5535 / 55°CTemperature application
A++ / A++A++ / A++A++ / A++A++ / A++Seasonal space heating energy efficiency class, aver-
age climate
15 / 1412 / 108 / 75 / 5kWRated heat output (P
designh
), average climate
6,702 / 8,4315,382 / 6,1363,882 / 4,4472,089 / 3,248kWhAnnual energy consumption space heating, average
climate
176 / 134174 / 132172 / 127188 / 131%Seasonal space heating energy efficiency, average
climate
35353535dBSound power level L
WA
indoors
15 / 1612 / 139 / 104 / 6kWRated heat output (P
designh
), cold climate
15 / 1512 / 128 / 84 / 5kWRated heat output (P
designh
), warm climate
10,040 / 13,6297,798 / 11,1976,264 / 8,8442,694 / 4,610kWhAnnual energy consumption space heating, cold cli-
mate
3,370 / 4,1832,759 / 3,4191,879 / 2,333872 / 1,398kWhAnnual energy consumption space heating, warm cli-
mate
144 / 113142 / 111139 / 108143 / 116%Seasonal space heating energy efficiency, cold climate
235 / 189229 / 185225 / 180252 / 179%Seasonal space heating energy efficiency, warm cli-
mate
62585551dBSound power level L
WA
outdoors
DATA FOR ENERGY EFFICIENCY OF THE PACKAGE
AMS 10-16 / HBS 05-
16
AMS 10-12 / HBS 05-
12
AMS 10-8 / HBS 05-
12
AMS 10-6 / HBS 05-6Model
SMOSMOSMOSMOControl module model
35 / 5535 / 5535 / 5535 / 55°CTemperature application
VIController, class
4.0%Controller, contribution to efficiency
180 / 138178 / 136176 / 131192 / 135%Seasonal space heating energy efficiency of the
package, average climate
A+++ / A++A+++ / A++A+++ / A++A+++ / A++Seasonal space heating energy efficiency class of the
package, average climate
148 / 117146 / 115143 / 112147 / 120%Seasonal space heating energy efficiency of the
package, cold climate
239 / 193233 / 189229 / 184256 / 183%Seasonal space heating energy efficiency of the
package, warm climate
The reported efficiency of the package also takes the controller into account. If an external supplementary boiler or solar heating is added to
the package, the overall efficiency of the package should be recalculated.
NIBE AMS 10Chapter 11 | Technical data50

Other manuals for Nibe AMS 10-8