TECHNICAL DOCUMENTATION
AMS 10-6 / HBS 05-6Model
Air-water
Exhaust-water
Brine-water
Water-water
Type of heat pump
Yes No
Low-temperature heat pump
Yes No
Integrated immersion heater for additional heat
Yes No
Heat pump combination heater
Average Cold Warm
Climate
Average (55 °C) Low (35 °C)
Temperature application
EN14511 / EN14825 / EN12102Applied standards
%131ƞ
s
Seasonal space heating energy efficiencykW5.3PratedRated heat output
Declared coefficient of performance for space heating at part load and at outdoor
temperature Tj
Declared capacity for space heating at part load and at outdoor temperature Tj
-1.88COPdTj = -7 °CkW4.7PdhTj = -7 °C
-3.26COPdTj = +2 °CkW2.8PdhTj = +2 °C
-4.72COPdTj = +7 °CkW1.8PdhTj = +7 °C
-6.47COPdTj = +12 °CkW2.7PdhTj = +12 °C
-1.88COPdTj = bivkW4.7PdhTj = biv
-1.77COPdTj = TOLkW4.1PdhTj = TOL
-COPdTj = -15 °C (if TOL < -20 °C)kWPdhTj = -15 °C (if TOL < -20 °C)
°C-10TOLMin. outdoor air temperature°C-7T
biv
Bivalent temperature
-COPcycCycling interval efficiencykWPcychCycling interval capacity
°C58WTOLMax supply temperature-0.99CdhDegradation coefficient
Additional heatPower consumption in modes other than active mode
kW1.2PsupRated heat outputkW0.007P
OFF
Off mode
kW0.012P
TO
Thermostat-off mode
ElectricType of energy inputkW0.012P
SB
Standby mode
kW0P
CK
Crankcase heater mode
Other items
m
3
/h2,526Rated airflow (air-water)VariableCapacity control
m
3
/hNominal heating medium flowdB35 / 51L
WA
Sound power level, indoors/outdoors
m
3
/hBrine flow brine-water or water-water heat pumpskWh3,248Q
HE
Annual energy consumption
NIBE Energy Systems Box 14 Hannabadsvägen 5 285 21 Markaryd SwedenContact information
51Chapter 11 | Technical dataNIBE AMS 10