Recommended alternative for leading off
condensation water
Drain indoors
Water seal
Joint
The condensation water is lead to an indoor drain (sub-
ject to local rules and regulations).
Route the pipe downward from the air/water heat pump.
The condensation water pipe must have a water seal to
prevent air circulation in the pipe.
KVR 10 spliced as illustrated. Pipe routing inside house
not included.
Stone caisson
Frost proof
depth
If the house has a cellar the stone caisson must be posi-
tioned so that condensation water does not affect the
house. Otherwise the stone caisson can be positioned
directly under the heat pump.
The outlet of the condensation water pipe must be at
frost free depth.
Gutter drainage
NOTE
Bend the hose to create a water seal, see illus-
tration.
LEK
Frostfritt
djup
Water seal
Frost free
depth
Water seal
LEK
From air/water heat
pump
The outlet of the condensation water pipe must be at
frost free depth.
Route the pipe downward from the air/water heat
pump.
The condensation water pipe must have a water seal
to prevent air circulation in the pipe.
The installation length can be adjusted by the size of
the water seal.
Caution
If none of the recommended alternatives is
used good lead off of condensation water must
be assured.
AMS 10Chapter 2 | Delivery and handling10