Technical specifications
Surrounding airOutdoor airExhaust air1x230 V
Output data according to EN 16 147
1.32 / 3.27
3
1.08 / 2.36
2
1.32 / 2.89
1
kW/-Capacity (P
H
)/COP
Additional power
1.3kWOutput immersion heater
Electrical data
230 V ~ 50 HzVRated voltage
9.1AMax operating current
10AMin. fuse rating
5-20WDriving power circulation pump
20-75WDriving power fan
IPX1BEnclosure class
Ventilation
Coarse 65%Filter type, exhaust air filter
Refrigerant circuit
R134AType of refrigerant
1430GWP refrigerant
0.38kgVolume
0.54tonCO
2
equivalent
2.2 / 22.0MPa/barCut-out value pressostat HP
Air flow requirement
-83-l/sMin. airflow with the temperature of the incoming air below
10 °C
254225l/sMin. airflow with the temperature of the incoming air at least
10 °C
10 - 37-10 - 3710 - 37°CTemperature range for compressor operation
Sound effect level according to EN 12 102
47.0dB(A)Sound power level (L
W(A)
)
4
Sound pressure levels according to EN ISO 11 203
43.0dB(A)Sound pressure level in the installation room (L
P(A)
)
5
Pipe connections
22mmHot water ext Ø
22mmCold water ext Ø
15mmSafety valve ext. Ø
160mmVentilation ext Ø
160/125mmFilter box ext. Ø
1
A20(12), luftflöde 50 l/s (180 m
3
/h)
2
A7(6), luftflöde 70 l/s (250 m
3
/h)
3
A20(12), luftflöde 50 l/s (180 m
3
/h)
4
The value varies with the fan speed selected. For more detailed sound data, including sound to ducts, visit nibe.eu.
5
The value can vary with the room’s damping capacity. These values apply at a damping of 4 dB.
37Chapter 12 | Technical dataNIBE F110