Loading...
StainlessCopperOther 1x230 V
Water heater
265litreVolume, hot water heater
0.2 / 2.0MPa/barMin pressure in water heater
1.0 / 10.0MPa/barMax pressure in hot water heater
1.0 / 10.00.9 / 9.0MPa/barOpening pressure, safety valve
56°CMax temperature with compressor
95°CMax temperature with additional heat
Capacity of hot water heating according to EN 16 147
1
365litreTap volume 40 °C at Normal comfort (V
max
)
42WIdle loss at Normal comfort (P
es
)
Dimensions and weight
2.8mLength, supply cable
600mmWidth
605mmDepth
2,030 - 2,060Height
2,110mmRequired ceiling height
127144kgWeight
-625 12 53RSK No.
066 025066 083Part No.
1
A20(12), air flow 50 l/s (180 m
3
/h). Comfort mode, normal.
Energy labelling
NIBE ABSupplier
F110
Surrounding air
F110
Outdoor air
F110
Exhaust air
Model
XLXLXL
Declared load profile
AAA
Water heating energy efficiency class, average cli-
mate
13195116%Water heating energy efficiency, average climate,
wh
1,2831,7781,452kWhAnnual energy consumption water heating, average
climate, AEC
545454°CThermostat setting
474747dBSound power level L
WA
indoors
13182116%Water heating energy efficiency, cold climate, ƞ
wh
131106116%Water heating energy efficiency, warm climate, ƞ
wh
1,2832,0371,452kWhAnnual energy consumption water heating, cold cli-
mate, AEC
1,2831,5891,452kWhAnnual energy consumption water heating, warm
climate, AEC
5.838.086.60kWhDaily electrical consumption, Q
elec
EN 16147Applied standards
NIBE F110Chapter 12 | Technical data38