EasyManuals Logo

Nibe F1145 5 User Manual

Nibe F1145 5
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #78 background imageLoading...
Page #78 background image
1285Miscellaneous
1950mmRequired ceiling height
2)
335325305kgWeight complete heat pump
135125110kgWeight only cooling module
665 405665 403665 401Part no.
1)
Max. permitted impedance in the mains connected point in accord-
ance with EN 61000-3-11. Start currents can cause short voltage
dips that could affect other equipment in unfavourable conditions.
If the impedance in the mains connection point is higher than that
stated it is possible that interference will occur. If the impedance in
the mains connection point is higher than that stated check with
the power supplier before purchasing the equipment.
2)
With feet dismantled the height is approx. 1650 mm.
Working range heat pump, compressor oper-
ation
The compressor provides a flow temperature up to 65
°C, the remainder (up to 70 °C) is obtained using the
additional heat.
8-12 kW 1x230V
0
10
20
30
40
50
60
70
-15 -10 -5 0 5 10 15 20 25 30 35
°C
p
°
C
7HPSHUDWXUH
,QFRPLQJ EULQH WHP
S
)ORZ SLSH
5HWXUQ SLSH
5 kW 1x230V
0
10
20
30
40
50
60
70
-15 -10 -5 0 5 10 15 20 25 30 35
°C
p
°C
7HPSHUDWXUH
,QFRPLQJ EULQH WHP
S
)ORZ SLSH
5HWXUQ SLSH
NIBE™ F1145Chapter 12 | Technical data76

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F1145 5 and is the answer not in the manual?

Nibe F1145 5 Specifications

General IconGeneral
BrandNibe
ModelF1145 5
CategoryHeat Pump
LanguageEnglish

Related product manuals