Symbol key
MeaningSymbol
Shut-off valve
Safety valve
Level vessel
Expansion vessel
Pressure gauge
P
Particle filter
Start guide
NOTE
There must be water in the climate system be-
fore the switch is set to "
".
1.
Turn the heat pump's switch (SF1) to "".
2.
Follow the instructions in the start guide in the heat
pump display. If the start guide does not start when
you start the heat pump, start it manually in menu
5.7.
Commissioning
The first time the heat pump is started a start guide is
started. The start guide instructions state what needs to
carried out at the first start together with a run through
of the heat pump’s basic settings.
The start guide ensures that the start-up is carried out
correctly and cannot be bypassed. The start guide can be
started later in menu 5.7.
Operation in the start guide
VWDUW JXLGH
$UURZV WR VFUROO WKURXJK ZLQGRZ LQ VWDUW JXLGH
1.
Turn the control knob until one of the arrows in the
top left corner (at the page number) has been
marked.
2.
Press the OK button to skip between the steps in the
start guide.
See page 39 for a more in-depth introduction to the heat
pump’s control system.
The start guide will be described under the following
points step-by-step.
1 Selection of language
VWDUW JXLGH
,I WKH VWDUW JXLGH LV OHIW RQ WKLV SDJH LW FORVHV
DXWRPDWLFDOO\ LQ
PLQ
Choose the language that you want the information to
be displayed in here.
Change language as follows:
1.
Turn the control knob until the language you require
is marked.
2.
Press the OK button.
3.
Turn the control knob until the arrow in the top left
corner (at the page number) has been marked.
4.
Press the OK button to access the next step in the
start guide.
2 Information
VWDUW JXLGH
:HOFRPH WR WKH VWDUW JXLGH IRU \RXU KHDW SXPS
$V ORQJ DV WKH VWDUW JXLGH LV DFWLYH QR IXQFWLRQ
LQ WKH KHDW SXPS ZLOO VWDUW DXWRPDWLFDOO\
7KH JXLGH ZLOO VKRZ XS ZLWK HDFK UHVWDUW RI WKH
KHDW SXPS XQWLO LW LV GHVHOHFWHG RQ WKH ODVW
SDJH
Information about the start guide for the heat pump is
shown here.
3 Setting "operating mode brine pump"
VWDUW JXLGH
LQWHUPLWWHQW
FRQWLQXRXV
GD\V FRQWLQXRXV
RSHUDWLQJ PRGH EULQH SXPS
op. mode
Setting range: intermittent, continuous, 10 days con-
tinuous
Default value: intermittent
Set the operating mode of the brine pump here.
NIBE™ F1145Chapter 6 | Commissioning and adjusting26