schedule blocking
The compressor can be scheduled to be blocked for up to two different
time periods here.
Menu
4.9.5
When scheduling is active the actual blocking symbol in the main menu
on the heat pump symbol is displayed.
DFWLYDWHG
VFKHGXOH VFKHGXOH
DOO
PRQ
WXHV
ZH
WKXU
IUL
VDW
VXQ
VFKHGXOH EORFNLQJ 
7LPH SHULRG %ORFNLQJ'D\
$FWLYDWHG
6FKHGXOH
&RQIOLFW
Schedule: The period to be changed is selected here.
Activated: Scheduling for the selected period is activated here. Set times
are not affected at deactivation.
Day: Select which day or days of the week the schedule is to apply to here.
To remove the scheduling for a particular day, the time for that day must
be reset by setting the start time to the same as the stop time. If the line
"all" is used, all days in the period are set for these times.
Time period: The start and stop time for the selected day for scheduling
are selected here.
Blocking: The desired blocking is selected here.
Conflict: If two settings conflict with each other a red exclamation mark
is displayed.
Blocking the compressor.
Blocking additional heat.
65NIBE™ F1255Chapter 3 | F1255 at your service