General points for the installation engineer
Transport and storage
F2025 should be transported and stored vertically.
Inspection of the installation
Current regulations require the heating installation to be in-
spected before it is commissioned. The inspection must be
carried out by a suitably qualified person and should be
documented. The above applies to closed heating systems.
If the heat pump is replaced, the installation must be inspec-
ted again.
Assembly
F2025 should be installed outdoors on a firm surface,
preferably a concrete foundation with ground stand or wall
mounting. The F2025 should not be positioned next to
sensitive walls, for example, next to a bedroom. Also ensure
that the placement does not inconvenience the neighbours.
Care must be exercised so that the heat pump is not
scratched during installation.
LEK
Do not place F2025 directly on the lawn or other non solid
surface.
Large amounts of condensation water as well as melt water
from defrosting can be produced. Provide good drainage at
the installation area and make sure water cannot run out
onto paths or the like during periods that ice can form. It is
also possible to install the accessory KVT 11, which is a col-
lecting trough for leading off condensation water. Condens-
ation water must be led off to a drain or similar.
LEK
Cirka 1 m
$SSUR[
P
Place F2025 on concrete pillars resting on macadma or
shingle for good drainage. The concrete pillars must be posi-
tioned so that the lower edge of the heat pump is at the
level of the average local snow depth, although a minimum
of 400 mm.
LEK
&RQGHQVDWLRQ ZDWHU
WURXJK
The distance between F2025 and the house wall must be at
least 350 mm. Clearance above F2025 should be at least one
metre. F2025 must not be placed so that recirculation
of outdoor air can occur. This causes lower output and
impaired efficiency.
350 mm
400 mm
3 m
Fritt utrymme bakom
Fritt utrymme framför
Fritt utrymme
Min. avstånd
vid användning
av flera F 2025
)UHH VSDFH
)UHH VSDFH EHKLQG
)UHH VSDFH LQ IURQW
0LQ GLVWDQFH ZKHQ XVLQJ VHYHUDO )
5F2025
For the Installer
General points for the installation engineer

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nibe F2025 and is the answer not in the manual?

Nibe F2025 Specifications

General IconGeneral
BrandNibe
ModelF2025
CategoryHeat Pump
LanguageEnglish

Related product manuals