28
F205P
For the Installer
Technical Data
Technical Data
Height (excl. feet 15-40mm) mm 2 095
Required ceiling height mm 2 185
Width mm 600
Depth mm 615
Net weight kg 195
Total volume litre 240
Volume in double jacket litre 70
Water heater volume litre 170
Expansion vessel volume, heating system litre 12
Expansion vessel volume, tap water litre 18
Supply voltage 230 V~ 1-phase + N
Max operating current A 16.7
Immersion heater power rating kW 3
Circulation pump power rating W 45
Exhaust air fan power consumption (DC) W 25-140
Compressor power rating W 550
COP* 3.3
Heating capacity* kW 1.5
Total power input* kW 0.45
Current* A 2.3
Protection IP21
Break pressure for high pressure pressostat MPa (bar) 2.45 (24.5)
Break pressure for low pressure pressostat MPa (bar) 0.15 (1.5)
Maximum pressure in water heater MPa (bar) 0.6 (6)
Maximum pressure in double jacket vessel MPa (bar) 0.3 (3)
Design pressure in double jacket volume MPa (bar) 0.25 (2.5)
Opening pressure T&P valve MPa (bar) 0.7 (7)
Opening temperature T&P valve °C 90-95
Refrigerant quantity g 420
Refrigerant type R290 (propane)
Min air flow, exhaust air m
3
/h 100
Exhaust air temperature range °C 16-30
Cut-in temperature for compressor (Controlled by a separate sensor) ° C 50 **
Cut-out temperature for compressor ° C 53 **
Cut-in temperature for immersion heater ° C 49 **
Cut-out temperature for immersion heater ° C 52 **
Inlet dry bulb temperature ° C 21
Water outlet temperature ° C 50
Setting area for the limiting valve ° C 38-55
Cut-out temperature, termostat for immersion heater ° C 70
Cut-out temperature, temperature limiter for immersion heater ° C 88
Cut-out temperature, temperature limiter for compressor ° C 88
Sound power level*** dB(A) 46-50
Sound level in room where installed**** dB(A) 42-46
LW***** dB(A) 50
LWD suction***** dB(A) 49
LWD discharge***** dB(A) 54
Part no. 089 890
IP 21