2
F205P
For Home Owners
General
In order to get the ultimate benefit from your heat pump NIBETM F205P you should read through the
For Home Owners section in this Installation and Maintenance Instruction.
F205P is an exhaust air heat pump. This means it utilises energy in ventilation air and uses this energy
for hot water and heating the house. A microprocessor ensures that the heat pump always works effi-
ciently.
For the installation engineer: Please, hand over to the home owner this manual after
finalised installation.
To be filled in when the heat pump has been installed
General
This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and
knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children
should be supervised to ensure that they do not play with the appliance. Rights to make any design or technical modifications are reserved.
©NIBE 2011.
Benchmark places responsibilities on both manufacturers and installers. The purpose is to ensure that customers are
provided with the correct equipment for their needs, that it is installed, commissioned and serviced in accordance with
the manufacturers instructions by competent persons and that it meets the requirements of the appropriate Building
Regulations. The Benchmark Checklist can be used to demonstrate compliance with Building Regulations and should
be provided to the customer for future reference.
Installers are required to carry out the installation, commissioning and servicing work in accordance with the Benchmark Code of Practice which is av-
ailable from the Heating and Hotwater Industry Council who manage and promote the Scheme.Visit www.centralheating.co.uk for more information.
Manufacter:
NIBE AB
Box 14
Järnvägsgatan 40
285 21 MARKARYD
SWEDEN
Maximum water
supply pressure
16 bar
Immersion heater R50 / 3000W /
230 V
Operating pressure, tap water 6 bar
Expansion vessel, tap water, char-
ge pressure
3,5 bar
Expansion vessel, heating water,
charge pressure
0,5 bar
Pressure reduction valve, setting 3,5 bar
Volume, water heater 170 litres
Mass, unit, filled with water 435 kg
Maximum primary working
pressure (heating side)
2,5 bar
Set opening pressure of
temperature and pressure valve
7 bar
Set opening pressure relief valve 6 bar
Set opening, temperature limiter,
immersion heater
88 °C
Set opening, temerature limiter,
compressor
88 °C
Heating up time from
15 °C to stop temperature for
compressor
7 h 8 min
Re-heating time, 70 % of
total volume (only compressor
working)
4 h 50 min
Benchmark checklist completed
Exhaust air flow and selected fan curve, high speed (Knob R51)
l/s m
3
/h ....................... Fan curve .............................
Exhaust air flow and selected fan curve, normal speed (Knob R52)
l/s m
3
/h ....................... Fan curve .............................
Setting the dip switch (S1) on the circuit board (34)
ON:
4 3 2 1
Heat emitter
Radiator .....................................
Underfloor heating coil
Date_________ Signed__________________________________