For Home Owners
Maintenance routines
General
The heat pump and its ventilation ducting require some
regular maintenance when the following points should be
checked.
The numbers in brackets refer to the section ”Component
locations”.
Cleaning the air filter
The heat pump air filter (63) should be cleaned regularly,
about four times a year.
1. Set the switch (8) to “0”.
2. The upper service cover is opened by pulling the lower
section outwards. The cover can then be lif-ted off.
3. Pull out the filter cassette (78).
4. Take out the filter and shake/vacuum off any dirt. Do
not use water or other liquids for cleaning.
5. Check that the filter is not damaged. New original fil-
ters can be ordered from a Nibe distributor.
6. Re-assembly takes place in the reverse order.
The cleaning time intervals vary depending on the amount
of dust in the exhaust air. Each third month an indicator
lamp “Midmost lamp” flashing to reminds about cleaning
the air filter. Note that the time will be set to zero by set-
ting the switch to “0”.