6
F205P
For Home Owners
Settings
Set actual time and weekday
1. Press the timer button once
M
. The first two digits in
the clock start to flash.
2. Use
M
or
to set the hours. Save the settings by
pressing the timer button once.
3. Use
M
or
to set the minutes. Save the settings by
pressing the timer button once.
4. Use
M
or
to set the weekday. Save the settings by
pressing the timer button once.
Changing the indoor temperature
A water borne heating system has a certain inertia. This
means that it can take several hours from when the
change was made until the desired temperature in the ac-
commodation is achieved. The size of the house, outdoor
temperature, hot water usage during the time etc. affects
how long the change takes.
E.g. You change the 05:00 setting of the clock thermostat
from 17 °C to 20°C. F205P starts to increase the tempera-
ture but it can take several hours for the heat pump to
achieve the desired change.
At 08:00 you change the setting again, from 20 °C to
17°C. The heat pump then starts to send out cooler wa-
ter to the heating system but it can take several hours be-
fore the water has cooled enough to achieve the desired
temperature.
Programme operating mode
Start by making settings for Monday to Friday:
SET 1 means period 1, SET 2 means period 2.
1. Hold in the timer button
M
until SET 1 appears in the
display.
2. Set the time at which you want period 1 to start to
apply. Set the time in the same way as you set the
clock previously, using
M
or
and the timer button.
3. Set the temperature you want indoors during period
1 by pressing
M
or
M
. Save the settings by pressing
the timer button once.
4. Set the time at which you want the period 1 setting
to stop being applied. Set the time in the same way
as you set the clock previously, using
M
or
and the
timer button.
5. Set the temperature you want indoors between peri-
ods 1 and 2 by pressing
M
or
. Save the settings by
pressing the timer button once.
6. SET 2 now appears in the display. Set the time at
which you want period 2 to start to apply. Set the
time in the same way as you set the clock previously,
using
M
or
and the timer button. The temperature
will be the same as you selected in period 1.
7. Set the time at which you want the period 2 setting
to stop being applied. Set the time in the same way
as you set the clock previously, using
M
or
and the
timer button.
Now make settings for Saturday and Sunday:
1. This is done in the same way as setting the tempera-
tures for weekdays (repeat steps 2-7).
Change operating mode
Press operating mode button (M) to switch between auto,
day, night and manual mode. Confirm using the timer but-
ton
M
.
If you want one indoor temperature during the daytime
and another indoor temperature during the night select
operating mode auto
M
.
If you want the day temperature for 24 hours select
M
and if you want the night temperature for 24 hours select
M
.
To change temperature at any point during the day, select
the manual mode. If the temperature in the accommoda-
tion is too low or too high, press
M
or
to increase or
decrease the temperature. Approximately 30 seconds after
the last button push, the thermostat returns to showing
the actual room temperature.
°C
Tid
17
18
19
20
08:00 09:00 10:00 11:00 12:0004:00 05:00 06:00 07:00
Inställd rumstemperatur
Verklig rumstemperatur
Settings
Time
Set room temperature
Actual room temperature
°C
17
18
19
20
12 14 16 18 20 22 2404 06 08 10
Inställd rumstemperatur
Tid
SET 1 SET 2
Time
Set room temperature

Table of Contents