Compressor (GQ10)
Used inMax operating
current
Winding resistance (at 20 °C)TypeManufacturer and model
F2120-817 A0.68 ΩScrollCopeland ZHW015
F2120-12
F2120-1633 A0.20 ΩScrollCopeland ZHW030
F2120-20
Inverter
The inverter's Status-LED indicates acc. to the table below:
StatusStatus LED
The compressor stopped, OKGreen, steady
The compressor stopped, OKGreen, flashing
Compressor is operational, OKOrange, steady
AlarmRed, steady
Broken circuit on terminal block X4Red, flashing
The inverter’s power LED lights orange continuously when the inverter is powered. (Applies only to F2120-16 and
20)
Used inInverter sizeVoltage
F2120-82.91x230 V
F2120-124.4
F2120-8
F2120-12
5.53x400 V
F2120-16
F2120-20
7.5
3-phase inverter
1-phase inverter
Power-LED
Status LED
F2120Chapter 4 | Component description14
4 Component description