Sensor placement
Data for temperature sensor return line (BT3),
condenser supply (BT12), fluid pipe (BT15)
and injection (BT81)
Voltage (VDC)Resistance
(kOhm)
Temperature
(°C)
3.256351.0-40
3.240251.6-35
3.218182.5-30
3.189133.8-25
3.15099.22-20
3.10574.32-15
3.04756.20-10
2.97642.89-5
2.88933.020
2.78925.615
2.67320.0210
2.54115.7715
2.39912.5120
2.24510.0025
2.0838.04530
1.9166.51435
1.7525.30640
1.5874.34845
1.4263.58350
1.2782.96855
1.1362.46760
1.0072.06865
0.8911.73970
0.7851.46975
0.6911.24680
0.6071.06185
0.5330.90890
0.4690.77995
0.4140.672100
Data for hot gas sensor (BT14)
Voltage (V)Resistance
(kOhm)
Temperature
(°C)
4.81118.740
4.7796.1345
4.7278.3050
4.6664.1155
4.5952.7660
4.5143.6465
4.4336.2670
4.3330.2775
4.2225.3880
4.1021.3785
3.9718.0790
3.8315.3395
3.6813.06100
3.5211.17105
3.369.59110
3.198.26115
3.017.13120
2.846.18125
2.675.37130
2.504.69135
2.334.10140