Enter menu 1.2 and select "normal".
External switch for changing the fan speed activated.
Check any external switches.
HIGH OR DISTRACTING VENTILATION
Filter blocked.
Clean or replace filter (see page 24).
The ventilation is not adjusted.
Order ventilation adjustment.
Fan speed in forced mode.
Enter menu 1.2 and select "normal".
External switch for changing the fan speed activated.
Check any external switches.
THE COMPRESSOR DOES NOT START
There is no heating requirement.
The heat pump does not call on heating nor hot water.
The heat pump defrosts.
Compressor blocked due to the temperature conditions.
Wait until the temperature is within the product’s working range.
Minimum time between compressor starts has not been reached.
Wait for at least 30 minutes and then check if the compressor has
started.
Alarm tripped.
Follow the display instructions.
NIBE F730Chapter 4 | Disturbances in comfort76