EasyManua.ls Logo

Nibe FIGHTER 310P - Visible functions; Extra hot water; Heating curve offset; Hidden functions

Nibe FIGHTER 310P
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Functions on the front panel
5
For Home Owners
FIGHTER 310P
Pressure gauge
Here the radiator circuit pressure is displayed.
Gauge graduation is 0 - 4 bar. Normal pressure
is 0.5 - 1.5 bar.
Upper lamp
Lit Compressor is operational.
Flashing
Not lit Compressor is not operational.
Centre lamp
Lit Automatic defrosting.
Flashing
Not lit Normal mode.
Lower lamp
Lit Immersion heater is operational.
Flashing Parts of the immersion heater are
disabled by an external controller
(load monitor, etc).
Not lit Immersion heater is not operational.
The two lamps next to the operating mode
selector indicate the chosen operating mode.
This should not be confused with the indicating
lamps in the numerical display.
Uppermost lamp Immersion heater
Lit The immersion heater may be con-
nected if necessary, i.e. when the
compressor cannot single handed
cover the heating requirement.
Not lit The immersion heater is disabled.
Bottom lamp Circulation pump
Lit The circulation pump is
operational.
Not lit The circulation pump is not opera-
tional. The shunt is valve is also
closed in this position.
Numerical display
In normal mode the boiler temperature is dis-
played here. The two digits on the left indicate
the channel number and the two on the right
the reading/setting of that channel.
In the event of a malfunction, an error message
is displayed alternately with channel number
and value. See Dealing with malfunctions
Indications on the numerical display.
NOTE! When switching from Standby mode R
to normal mode 1 the numerical display can
remain dimmed for a brief period. This can also
occur at extremely low outdoor temperatures.
Extra hot water
Pressing the Extra hot water button raises the
boiler temperature to about 60°C, giving
increased water capacity for about 24 hours. In
this mode, the built-in lamp is constantly lit.
Pressing the button again gives a permanent
function which raises temperature of the hot
water at regular intervals. In this mode, the
built-in lamp flashes.
Pressing the button again resets the above
functions.
Heating curve offset
With the Heating curve offset button you can
change the offset of the heating curve and thus
the room temperature.
E
A
B
C
D
F
Operating mode indications
Operating mode
When the heat pump is started, all functions
(immersion heater, circulation pump and auto-
matic heating control system) are running.
Pressing the Operating mode button once dis-
ables the immersion heater.
Pressing it once more stops the circulation
pump as well.
Pressing it yet again reconnects the immersion
heater and the circulation pump.
Channel selection
Use the Channel selection button to browse
forward through the display window channels to
see the required reading or setting.
Available readings/settings include:
1 Boiler temperature
2 Flow temperature
3 Outdoor temperature
5 Extract air temperature
Normallythe display always shows Channel 1.
When you have browsed through the channels,
channel 1 returns after a while.
Heating curve selection
Use the Heating curve selection knob to set
the automatic heating control system; see
under Room temperature.
G
H
I
J
Avfrostnin
g
p
å
g
å
r
El
p
atron i drif
t
Blinkande indikerin
g
:
S
e instruktion bako
m
Kanal Panntemp/värde
Power switch
with 3 modes 0 - 1 - R:
0 Heat pump off.
1 Normal mode. All control functions connect-
ed.
R Standby. This mode is used during start up
and with any operating disruptions.
Indicator lamps
Val, värmekurva
155
10
0
20
Cirk.pump
Elpatron
Drift-
läge
Kanal-
val
Hidden functions
Visible functions

Other manuals for Nibe FIGHTER 310P

Related product manuals