Nibe FIGHTER 1330 Specifications

General IconGeneral
Cooling Capacity11.5 kW
Power Output5 - 15 kW (depending on model)
Power Input Cooling3.1 kW
COP Heating4.2
Sound Power Level Outdoor UnitN/A (No outdoor unit)
Dimensions Outdoor Unit (HxWxD)N/A (No outdoor unit)
Weight Outdoor UnitN/A (No outdoor unit)

Summary

System Description

Principle of Operation

Explains the fundamental working principle of the heat pump.

General Information for the Installer

Installation

Instructions for the correct installation of the heat pump.

Pipe Connections

Pipe Connections (Heating Medium)

Specifics for connecting the heating medium circuits.

Pipe Connections (Brine)

Details for connecting the brine circuit.

Filling and Venting the Collector System

Procedure for filling and venting the collector system.

Filling the Heating Medium System

Procedure for filling the heating medium system.

Docking Options

Electrical Connections

Connection of External Sensors

Details on connecting external sensors to the unit.

Connection Details

Specifics on connecting power and control signals.

Description of Functions - Start Up

Inspection Procedure

Step-by-step guide for initial inspection before operation.

Starting Up a Single FIGHTER 1330

Procedure for starting up a single heat pump unit.

Starting Up Multiple FIGHTER 1330s

Procedure for starting up a system with multiple heat pumps.

Operating Type Selection

How to select the operating mode for each unit.

Master / Slave Configuration

Detailed steps for configuring Master/Slave units.

Description of Functions - Basic Functions

Heating Function

Details on the heating mode, including operating modes.

Hot Water Production Settings

Menu settings for hot water production.

Extra Hot Water Function

Configuration and operation of the Extra Hot Water function.

Electrical Additional Heater

Details on controlling the electrical additional heater.

Connection of Electrical Additional Heater

Wiring diagrams for the electrical additional heater.

Oil Boiler Operation

Description of how the oil boiler is controlled.

HPAC (Heating and Cooling)

Details on the HPAC system for heating and cooling.

Floor Drying Function

Description of the integrated floor drying function.

Room Control

Information on connecting and using room control devices.

Description of Functions - Expansion Card 1

Hot Water Circulation Pump

Control and connection of the hot water circulation pump.

Pool Operation

Details on connecting and operating pool heating.

Description of Functions - Expansion Card 2

Groundwater Pump

Control and connection of the groundwater pump.

Passive Cooling with 4 Pipe System

Details on passive cooling using a 4-pipe system.

Passive Cooling with 2 Pipe System

Details on passive cooling using a 2-pipe system.

Combined Cooling/Heating Modes with Accumulators

Operation modes for combined cooling/heating with accumulators.

External Control Settings

Electrical Connection for External Control

Wiring for external control of additional heat and compressor.

Control Menu Navigation

Changing Parameters

Instructions on how to change parameter values.

Menu 5.0 Heat Pump

Detailed settings and status for heat pump modules.

Menu 6.0 External Units

Settings for external units and accessories.

Menu 9.0 Service Menus

Access to service-specific settings and diagnostics.

Technical Specifications

Technical Data Table

Detailed technical specifications for different models.

Actions with Operating Disturbances

Low Room Temperature Issues

Troubleshooting steps for low room temperature.

High Room Temperature Issues

Troubleshooting steps for high room temperature.

Low Hot Water Temperature or No Hot Water

Troubleshooting for issues with hot water supply.

Alarm with Automatic Resetting

Alarms that reset automatically after conditions are met.

Com. Error Alarm

Troubleshooting communication errors between units.

Constant Alarm Types

Overview of constant alarms and their causes.

HP-Alarm (High Pressure)

Troubleshooting high pressure alarms.

LP-Alarm (Low Pressure)

Troubleshooting low pressure alarms.

MS-Alarm (Motor Cut-out)

Troubleshooting motor cut-out alarms.

Lev.sens.alarm (Level Sensor Alarm)

Troubleshooting level sensor alarms in the collector circuit.