EasyManua.ls Logo

Nibe FIGHTER 310P User Manual

Nibe FIGHTER 310P
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
INSTALLATION AND MAINTENANCE INSTRUCTION
FIGHTER 310P
230V
MOS GB 0850-4
FIGHTER 310P
511350
LEK
Fighter 310P
Fighter 310P

Table of Contents

Other manuals for Nibe FIGHTER 310P

Question and Answer IconNeed help?

Do you have a question about the Nibe FIGHTER 310P and is the answer not in the manual?

Nibe FIGHTER 310P Specifications

General IconGeneral
BrandNibe
ModelFIGHTER 310P
CategoryHeat Pump
LanguageEnglish

Summary

General

Installation Details Record

Section for recording installation details like serial number, date, and installer.

System description

Principle of operation

Details how the heat pump extracts energy from ventilation air.

System diagram

Illustrates the air flow and heat distribution within the house.

Front panel

Upper (visible) part of the front panel

Identifies and explains controls like pressure gauge and switch.

Visible functions

Details the functions of the pressure gauge, power switch, and indicator lamps.

Extra hot water

Explains the function of the 'Extra hot water' button.

Heating curve offset

Describes how to adjust the heating curve offset for room temperature.

Hidden functions

Details hidden functions like operating mode indications and channel selection.

Lower (hidden) part of the front panel

Identifies controls like indicator lamps, operating mode, and channel selection.

Room temperature

Automatic heating control system

Details how the system regulates indoor temperature based on outdoor conditions.

Default setting

Guide to setting the basic heating using knobs.

Readjustment of basic settings

Guidance on adjusting settings for cold and warm weather conditions.

Changing the room temperature manually

Instructions for temporarily or permanently altering the room temperature.

Maintenance routines

Cleaning the air filter

Instructions for cleaning the heat pump's air filter.

Cleaning the ventilation devices

Procedure for cleaning the building's ventilation devices.

Checking the safety valves

Procedure for checking the safety valves.

Pressure gauge

Explains the function and normal reading of the pressure gauge.

Extract air temperature

Information on checking extract air temperature.

General points for the installation engineer

Transport and storage

Guidelines for transporting and storing the heat pump.

Handling

Precautions for handling the heat pump, especially the refrigerant.

Lifting straps

Details on removing lifting straps.

Erecting the heat pump

Instructions on positioning and mounting the heat pump.

Hard water areas

Notes on installing the heat pump in hard water areas.

Inspection of the installation

Requirements for inspecting the heating installation before commissioning.

Temperatures in FIGHTER 310P

Normal temperature levels in the boiler or water heater.

Pipe connections

General

Covers pipe installation norms, system requirements, and pressure limits.

Kitchen duct

Notes that the kitchen duct must not be connected.

Tap water connection

Expansion vessel, tap water

Instructions for installing the expansion vessel for tap water.

Pump and pressure drop diagrams

Presents pump performance and pressure drop characteristics.

Ventilation connection

Ventilation flow

Specifies ventilation flow requirements and installation area ventilation.

Duct installation

Guidelines for duct installation, earthing, and insulation.

Fan diagram

Presents a diagram showing available ventilation capacity.

Electrical connections

Connection

Details on electrical connections and precautions.

Power rating as set at the factory

Information on the factory-set output power of the immersion heater.

Resetting the temperature limiter

Procedure for resetting temperature limiters.

Max current

Table showing immersion heater output, max current, and breaker.

Immersion heater

Details about the immersion heater and its safety limiter.

Setting the fan capacity

Blocking immersion heater operation

Commissioning and adjusting

Connecting the outside sensor

Instructions for installing the outside sensor.

Centralised load control and load monitor

Details on disconnecting immersion heater steps using load control.

Commissioning and adjusting

Preparations

Checks and steps before filling the water heater and heating system.

Filling the water heater and the heating system

Procedure for filling the water heater and heating system.

Venting the heating system

Instructions for venting air from the heat pump and heating system.

Starting

Steps to start the heat pump and circulation pump.

Commissioning and adjusting

Setting the ventilation

Adjusting ventilation flows and fan transformer settings.

Readjustment

Information on readjusting the system after filling and venting.

Draining the heating system

Procedure for draining the heating water.

Emptying the water heater

Steps to properly empty the water heater.

Cleaning the system / Flushing out of the hot water and central heating system

Procedure for flushing and refilling the hot water and heating systems.

Setting the automatic heating control system

Heating curve offset -2

Diagram and explanation for heating curve offset setting.

Heating curve offset 0

Diagram and explanation for heating curve offset setting.

Heating curve offset +2

Diagram and explanation for heating curve offset setting.

Setting using diagrams

Explains how to use diagrams to set the automatic heating control.

Dealing with malfunctions

Low temperature or a lack of hot water

Troubleshooting steps for low hot water temperature or supply.

Low or a lack of ventilation

Troubleshooting steps for insufficient ventilation.

Low room temperature

Troubleshooting steps for low room temperature.

High room temperature

Troubleshooting steps for high room temperature.

Dealing with malfunctions

Indications on the display

Explains fault codes and symbols shown on the numerical display.

Fault code A-01 on the numerical display

Indicates the air filter needs cleaning.

Fault code A-03 on the numerical display

Indicates tripped high or low pressure pressostat.

Resetting pressostats

Procedure for resetting tripped pressure switches.

Dealing with malfunctions

Resetting the miniature circuit breakers

Instructions for resetting miniature circuit breakers (MCBs).

High extract air temperature

Troubleshooting high extract air temperature.

Helping the circulation pump to start

Procedure to assist the circulation pump in starting.

Service

Opening the front panel

Instructions for safely opening the front panel for access.

Channel description

Explains the meaning of different channels on the display.

Service

Refrigerant system

Safety and regulatory requirements for refrigerant system work.

Electrical circuit diagram

Changing the output

Instructions on how to change the heat pump's output power.

Component locations

Component locations

Labeled diagrams identifying the placement of components.

List of components

A comprehensive list of all components with their numbers and functions.

Dimensions

Dimensions and setting-out coordinates

Detailed measurements and spatial requirements for installation.

Measuring principle

Illustrates the measuring principle for components.

Technical specifications

Technical specifications

Comprehensive technical data including dimensions, power, and sound levels.

COP and heating capacity according to EN 14511-2_2004

Performance data according to specific European standards.

Enclosed kit

Accessories

Related product manuals