EasyManua.ls Logo

Nibe FIGHTER 310P - Lower (hidden) part of the front panel

Nibe FIGHTER 310P
32 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Room temperature
FIGHTER 310P
For Home Owners
6
Extra varmvatten
Avfrostnin
g
p
å
g
å
r
El
p
atron i drif
t
Blinkande indikerin
g
:
S
e instruktion bako
m
luckan!
Kanal Panntemp/värde
Förskjutning,
värmekurva
(öka/minska värme)
Extra varmvatten
Val, värmekurva
155
10
+2-2
0
20
Cirk.pump
Elpatron
Drift-
läge
Kanal-
val
Återställning av
överhettningsskydd
maxmin
Skellefteå
Umeå
Örnsköldsvik
Sundsvall
Hudiksvall
Gävle
Stockholm
Visby
Luleå
Jönköping
Göteborg
Borås
Halmstad
Helsingborg
Malmö
Växjö
Karlskrona
Ystad
Simrishamn
Örebro
Uppsala
Västerås
Söderhamn
11 (5)
10 (5)
9 (5)
8 (4)
8
(
4
)
9
(
4
)
11 (5)
11 (5)
12 (6)
Markaryd
Karta med rikt
-
v
ä
ö
r v
a
l
av
v
ä
ej projekterad
e
v
ä
r
de
n finn
s.
9 (4)
9 (5)
Gällivare
Östersund
Kiruna
Falun
Hässleholm
Karlstad
Kalmar
Norrköping
Linköping
Val, värmekurva:
Inställning beror på geografiskt
läge och typ av uppvärmnings-
system (radiatorvärme, golv-
värme etc.).
Förskjutning, värmekurva:
Finjustering av temperatur till
radiatorer/golvslingor.
Värmekurvan parallellförskjuts.
Normalt mellan -2 och +2.
För utförligare information,
se skötselanvisningen.
Exempel:
Markaryd. Område 10 (5).
Ställ in värmekurva 10, för-
skjutning -2 för radiatorsystem
respektive 5, förskjutning -1
för golvvärmesystem.
The indoor temperature depends on several factors.
During the hot season, solar radiation and heat given
off by people and equipment are sufficient to keep the
house warm. When it gets colder outside, the heating
system must be started. The colder its gets, the hotter
the radiators must be.
This adjustment is made automatically, however the
basic settings must first be made on the boiler, see the
section Room temperature Default setting.
The basic heating is set with the Heating curve selec-
tion knob and with the Heating curve offset knob.
If you do not know the correct settings use the basic
data from the map opposite.
If the required room temperature is not obtained, read-
justment may be necessary.
NOTE! Wait one day between settings so that the tem-
peratures have time to stabilise.
Readjustment of basic settings.
Cold weather conditions
If the room temperature is low, increase the heating
curve selection setting by one step.
If the room temperature is high, reduce the heating
curve selection setting by one step.
Warm weather conditions
If the room temperature is low, increase the heating
curve offset setting by one step.
If the room temperature is high, reduce the heating
curve offset setting by one step.
Changing the room temperature manually.
If you want to temporarily or permanently lower or
raise the indoor temperature relative to the previously
set temperature, turn the
Heating curve offset knob
anticlockwise or clockwise respectively. One scale
marking corresponds to a change of about one degree
in the room temperature.
NOTE! An increase in the room temperature may be
inhibited by the radiator or floor heating thermostats, if
so these must be turned up.
Default setting
Automatic heating control system
Changing the room
temperature

Other manuals for Nibe FIGHTER 310P

Related product manuals