Troubleshooting
If the malfunction does not appear in the display or NIBE FLM is not
connected to a compatible heat pump, the following tips can be used:
BASIC ACTIONS
Start by checking the following items:
The switch's position.
That the heat pump is running or that the supply cable to NIBE FLM
is connected.
Group and main fuses of the accommodation.
The property's earth circuit breaker.
LOW OR A LACK OF VENTILATION
Filter blocked.
Clean or replace filter (see page 10).
The ventilation is not adjusted.
Order ventilation adjustment.
Exhaust air device blocked or throttled down too much.
Check and clean the exhaust air devices (see page 10).
Fan speed in reduced mode.
If NIBE FLM is connected to a compatible heat pump: Enter menu
1.2 and select “normal”.
If NIBE FLM is connected to another heat pump: Contact your in-
staller!
External switch for changing the fan speed activated.
Check any external switches.
HIGH OR DISTRACTING VENTILATION
Filter blocked.
Clean or replace filter (see page 10).
The ventilation is not adjusted.
Order ventilation adjustment.