External supply temperature sensor
Temperature sensor
External supply line sensor (BT63) is installed, depend-
ing on the docking, according to the outline diagram
in this manual.
LEK
LEK
E
Install the temperature sensors using cable ties, with the
heat conducting paste and aluminium tape. Then insu-
late them with the supplied insulation tape.
NOTE
Sensor and communication cables must not be
placed near power cables.
Connect the supply temperature sensor (BT63) to any
AUX input on the input board in the main product.
SMO 40
AA3-X6
1
2
3
4
5
6
7
8
9
BT63
10
LEK
AA3-X6
Program settings
Program setting for OPT 10 can be performed via the
start guide or directly in the menu system in NIBE the
heat pump/indoor module/control module.
Caution
Also, see the Installer Manual for the heat
pump/indoor module/control module.
Start guide
The start guide appears upon first start-up after heat
pump installation, but is also found in menu 5.7.
Menu system
If you do not make all settings via the start guide or need
to change any of the settings, this can be done in the
menu system.
Menu 5.2.4. -system settings
Activating/deactivating of accessories.
Select: GBM communication module
Menu 5.3.15 - GBM communication module
Setting the start values for the gas boiler.
Technical data
OPT 10
12 VDC (45-80mA)VDC (mA)Rated voltage
80x80x30mmDimensions
067 513Part No.
7331421335369EAN no.
17OPT 10 | GB