MENU 4.2.3 - SG READY
Here, you set the part of your climate system (e.g. room
temperature) that will be affected on activation of "SG
Ready". The function can only be used in mains networks
that support the "SG Ready" standard.
Affect room temperature
With low price mode on "SG Ready", the parallel offset for
the indoor temperature is increased by "+1". If a room sensor
is installed and activated, the desired room temperature is
increased instead by 1 °C.
With overcapacity mode on "SG Ready", the parallel offset
for the indoor temperature is increased by "+2". If a room
sensor is installed and activated, the desired room temper-
ature is increased by 2 °C instead.
Affect hot water
With low price mode on "SG Ready", the stop temperature
for the hot water is set as high as possible with compressor
operation only (immersion heater not permitted).
In the case of overcapacity mode on "SG Ready", the hot
water is set to large demand mode (immersion heater per-
mitted).
NOTE
The function must be connected to two AUX inputs
and be activated in menu 7.4 "Selectable in/out-
puts".
MENU 4.2.5 - SMART PRICE ADAPTION™
Range
Alternative: on/off
Affect room temp heating
Alternative: on/off
Degree of effect
Setting range: 1 – 10
Affect hot water
Alternative: on/off
Degree of effect
Setting range: 1 – 4
Deactivate Smart control (HW)
Alternative: on/off
4
This function can only be used if your electricity supplier
supports Smart price adaption™, if you have an hourly tariff
agreement and an active myUplink account.
Smart price adaption™ adjusts some of the installation’s
consumption during the day to those periods with the
cheapest electricity tariff, which can provide savings if you
are on an hourly rate based electricity contract. The function
is based on downloading hourly rates for the next day via
myUplink, and for this reason an Internet connection and
an account for myUplink are required.
Range: Contact your electricity supplier for information
about which area (zone) the installation belongs to.
Degree of effect: You can choose which parts of the install-
ation will be affected by the electricity price and to what
extent; the higher value you select, the greater the effect
the electricity price has.
NOTE
A value that is set high may result in increased
savings, but may also affect the comfort.
MENU 4.4 - WEATHER CONTROL
Activate weath. contr.
Alternative: on/off
Factor
Setting range: 0 – 10
You can select whether you want S1156 to adjust the indoor
climate based on the weather forecast here.
You can set factor for outdoor temperature. The higher the
value, the greater the effect from the weather forecast.
Caution
This menu is only visible if the installation is con-
nected to myUplink.
MENU 4.5 - AWAY MODE
In this menu, you activate/deactivate "Away mode".
When away mode is activated, the following functions are
affected:
• the setting for heating is lowered slightly
• the setting for cooling is raised slightly (if cooling access-
ory is installed)
• the hot water temperature is lowered if demand mode
"large” or "medium” is selected
• The AUX function "Away mode" is activated.
If you want, you can select for the following functions to be
affected:
• ventilation (accessory is required)
• hot water circulation (accessory or use of AUX is required)
4
See menu 2.2 for more information about Smart Control.
49Chapter 9 | Control - MenusNIBE S1156