Detailed information about the accessories and complete
accessories list available at nibe.eu.
Not all accessories are available on all markets.
ACTIVE/PASSIVE COOLING IN 4-PIPE SYSTEM
ACS 45
Part no 067 195
ACTIVE/PASSIVE COOLING HPAC S40
The accessory HPAC S40 is a climate exchange module that is to
be included in a system with S1255.
Part no. 067 624
DOCKING KIT PVT 40
PVT 40 enables S1255 to use PVT-panels as brine-source.
Part no. 057 245
EXTERNAL ELECTRIC ADDITIONAL HEAT ELK
These accessories require accessories card AXC 40 (step controlled
addition).
ELK 213
7–13 kW, 3 x 400 V
Part no. 069 500
ELK 15
15 kW, 3 x 400 V
Part no. 069 022
EXTRA SHUNT GROUP ECS 40/ECS 41
This accessory is used when S1255 is installed in houses with two
or more different heating systems that require different supply
temperatures.
ECS 41 (approx.
80-250 m²)
Part no 067 288
ECS 40 (Max 80 m²)
Part no 067 287
FREE COOLING PCS 44
This accessory is used when S1255 is installed in an installation
with passive cooling.
Part no 067 296
HUMIDITY SENSOR HTS 40
This accessory is used to show and regulate humidity and temper-
atures during both heating and cooling operation.
Part no. 067 538
EXHAUST AIR MODULE FLM S45
FLM S45 is an exhaust air module designed to combine recovery
of mechanical exhaust air with ground source heating.
Bracket BAU 40
Part no. 067 666
FLM S45
Part no. 067 627
HRV UNIT ERS
This accessory is used to supply the accommodation with
energy that has been recovered from the ventilation air. The
unit ventilates the house and heats the supply air as neces-
sary.
ERS 20-250
1
Part no. 066 068
ERS S10-400
1
Part no. 066 163
ERS 30-400
1
Part no. 066 165
1
A preheater may be required.
BASE EXTENSION EF 45
This accessory is used to create a larger connection area under
S1255.
Part no. 067 152
AUXILIARY RELAY HR 10
Auxiliary relay HR 10 is used to control external 1 to 3 phase loads
such as oil burners, immersion heaters and pumps.
Part no 067 309
COMMUNICATION MODULE FOR SOLAR
ELECTRICITY EME 20
EME 20 is used to enable communication and control between in-
verters for solar cells from NIBE and S1255.
Part no. 057 188
LEVEL MONITOR NV 10
Level monitor for extended checks of the brine level.
Part no. 089 315
PASSIVE COOLING PCM S40/S42
PCM S40/42 makes it possible to obtain passive cooling from rock,
groundwater or surface soil collectors.
Part no. 067 625 / 067 626
POOL HEATING POOL 40
POOL 40 is used to enable pool heating with S1255.
Part no 067 062
FILLING VALVE KIT, BRINE 25/32
Valve kit for filling brine in the collector hose. Includes particle filter
and insulation.
KB 32 (max. 30 kW)
Part no. 089 971
KB 25 (max. 12 kW)
Part no. 089 368
NIBE S1255Chapter 12 | Accessories64
Accessories