This function can only be used in
mains networks that support the "SG
Ready"-standard .
Make settings for the function "SG
Ready" here.
affect room temperature
Here you set whether room temperat-
ure should be affected when activat-
ing "SG Ready".
Menu
4.1.5
With low price mode on "SG Ready" the parallel offset for the indoor
temperature is increased by "+1". If a room sensor is installed and activated,
the desired room temperature is instead increased by 1 °C.
With over capacity mode on "SG Ready" the parallel offset for the indoor
temperature is increased by "+2". If a room sensor is installed and activated,
the desired room temperature is instead increased by 2 °C.
affect hot water
Here you set whether the temperature of the hot water should be affected
when activating "SG Ready".
With low price mode on "SG Ready" the stop temperature of the hot water
is set as high as possible at only compressor operation (immersion heater
not permitted).
With over capacity mode of "SG Ready" the hot water is set to "luxury"
(immersion heater permitted).
affect cooling (accessory required)
Here you set whether room temperature during cooling operation should
be affected when activating "SG Ready".
With low price mode of "SG Ready" and cooling operation the indoor
temperature is not affected.
With over capacity mode on "SG Ready" and cooling operation, the parallel
offset for the indoor temperature is reduced by "-1". If a room sensor is
installed and activated, the desired room temperature is instead reduced
by 1 °C.
51NIBE™ SMO 20Chapter 3 | SMO 20 – at your service