EasyManua.ls Logo

Nibe VEDEX 4000 - Boiler (STB) Temperature Limiter; Resetting the STB Temperature Limiter; STB Limiter Tripping Warning

Nibe VEDEX 4000
36 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
27VEDEX 4000
Boiler (STB) Temperature Limiter
Resetting of the boiler temperature limiter (STB)
Tripping of the boiler’s temp limiter warns of
incorrect operation of the System, which re-
quires investigation.
NOTE
1. The STB temperature limiter is available on the
left cover side in the upper part.
Temperature
limiter
2. Disconnect the boiler power supply cables.
3. Loosen the screw holding the plate which closes
the access to STB switch. Now expose the STB
temperature limiter by moving the plate down.
4. Press down STB temperature limiter, shift back
the blank plate and tighten the screw holding it.

Related product manuals