38 NIBE VVM 300
Miscellaneous
Menu 7.1 Date
The current date is set here.
Menu 7.2 Time
Here the current time is set.
Menu 7.3.0 Temp set back
Settings, e.g. for night reduction can be selected in the
sub-menus to this menu.
Menu 7.3.1 Set back time
The time for the day change, e.g. night reduction is chosen
here.
Menu 7.3.2 Set back temp +/-
Changes to the flow temperature with a day change, e.g.
night reduction are set here. The value can be adjusted be-
tween -10 and +10 steps for offset of the heat curve.
Meny 7.3.3 Shunt system
Here you select which heating system the room adjustment
should affect. Can be set at ”System 1”, ”System 2”, or
”System 1+2”.
Menu 7.3.4 Return
Return to menu 7.3.
Menu 7.4.0 Extra hot water
Settings for control of extra hot water can be made in the
sub-menus to this menu.
Menu 7.4.1 – 7.4.7 XHW Monday – Sunday
Here you select the period for respective days when extra
hot water should be activated. Hours and minutes for both
start and stop are shown. Equal values mean that extra hot
water is not activated.
Menu 7.4.8 Return
Return to menu 7.4.0
Meny 7.5.0 Vacation set back
Settings concerning vacation set back are made on the
sub-menus to this menu.
When the vacation function is active, the flow temperature
is lowered according to the chosen setting, and the hot
water heating as well as pool heating can be turned off.
When the vacation function is deactivated, the heat pump
7.0 Clock
Menu explanation
is heating the water for one hour, before extra hot water is
activated.
Meny 7.5.1 Vacation begins
Here you select the start date for the vacation set back. The
date is changed by pressing the enter-button. The vacation
set back starts at 12:00 midnight the chosen date.
The same date in menu 7.5.1 and 7.5.2 deactivates the
vacation set back.
Meny 7.5.2 Vacation ends
Here you select the end date for the vacation set back. The
date is changed by pressing the enter-button. The vacation
set back ends at 11:59 p.m. the chosen date.
The same date in menu 7.5.1 and 7.5.2 deactivates the
vacation set back.
Meny 7.5.3 Shunt system
Here you select which heating system shall be affected by
the vacation set back.
Meny 7.5.4 Offset heating curve
Here you select the heating curve offset during the vaca-
tion set back. The value can be adjusted between -10 and
+10. The factory setting is -5.
If the selected heating system has a room sensor, the set
back is given in degrees instead.
7.5.5 HW deactivated
Here you can select wether hot water heating shall be tur-
ned off during the vacation set back. Can be set to ”Yes”
or ”No”. The factory setting is ”Yes”.
7.5.6 Pool deactivated
Here you can select wether pool heating shall be turned off
during the vacation set back. Can be set to ”Yes” or ”No”.
The factory setting is ”Yes”.
7.5.7 Return
Return to menu 7.5.0.
Menu 7.6 Return
Return to menu 7.0.