EasyManuals Logo

Nice CBOX1050 User Manual

Default Icon
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #37 background imageLoading...
Page #37 background image
CBOX1050
Installation and Programming Manual
3737
MX4682 Rev. D ©2021
FORCE BUTTON MENU:
Amount of force needed to cause the gate to stop
and reverse when hitting an obstacle.
STATIC: Set sensitivity to constant force on a
scale of 1 to 10 (1 being the most sensitive).
DYNAMIC: Set sensitivity of sudden impact
force to the moving gate on a scale of 1 to 10
(1 being most sensitive). 0 = OFF.
EXIT: Exits the FORCE menu.
FORCE
1.Stac :5
FORCE
2.Dynamic :5
FORCE
3.ESC
FORCE
EXIT
(min-max
sensivity)
(min-max
sensivity)
(Low
to High)
OK
Press
SPEED
1. Max :100
SPEED
2. Standard :100
SPEED
3. Low :50
SPEED
4. SlowDown :50
ACCELERATION
5. Max :10
ACCELERATION
6. Standard :5
ACCELERATION
7. ESC
SPEED
EXIT
Press
OK
SPEED BUTTON MENU:
Sets the speed of the gate under various conditions.
MAX: Sets limit of max allowed gate speed on scale of 20%
to 100% (20% is lowest setting). It is recommended to set to
default of 100.
STANDARD: Sets limit of the gate speed during normal
movement (not soft start/stop) on scale of 20% to 100%
(20% being the lowest setting). It is recommended to set to
default of 100.
LOW: Sets limit of the gate speed while in LEARNING mode
and when moving in SLOW, on scale of 20% to 100% (20%
being the lowest setting). Recommended not to be set lower
than 50. Default setting depends upon learning parameters
SLOWDOWN: Set gate speed when approaching the open or
close limits on scale of 20% to 100% (20% being the lowest
setting). Recommended not to set lower than 50% for slide
gates. The lower this setting the less power the operator will
have when approaching the limit. Setting too low could cause
a stall condition prior to open/close limit.
» ACCELERATION: Adjusts the rate of acceleration/
deceleration when the motor starts and stops moving:
» MAX: Sets the limit of gate acceleration and
deceleration when reversing the gate after
an obstacle has been detected by
the UL/Edge or current sense feature
(Force). Settings from 3 to 10, with 10 being the highest
rate of gate acceleration.
» STANDARD: Sets the limit of the gate acceleration and
deceleration in normal operation. Settings from 1 to
10, with 10 being the highest rate of gate acceleration.
* *TO PREVENT DAMAGE TO THE GATE OR THE
CONTROLLER USE LOWER ACCELERATION SETTINGS
FOR HEAVIER GATES.
» ESC: Exit the SPEED / ACCELERATION menus.
SPEED Button
FORCE Button
OK
20%
100%
OK
3
10
OK
1
10
OK
20%
100%
OK
20%
100%
OK
20%
100%
OK
1
10
OK
0
10

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nice CBOX1050 and is the answer not in the manual?

Nice CBOX1050 Specifications

General IconGeneral
BrandNice
ModelCBOX1050
CategoryEnclosure
LanguageEnglish