Table A7 Z-Wave parameter setting
Parameter: 1. Paremeter Menu No. E20 Temp. Unit
Description: 0: Celsius
1: Fahrenheit
Available settings: 0-1
Default setting: 1 Parameter size: 1 [byte]
11
Z-WAVE PARAMETER SETTING
Parameter: 2. Automatic Temperature Value Reporting (Celsius)
Description: Unit 0.1
0: OFF:
3-255: n *0.1,automatically report to gateway when temperature variation greater than this value.
Available settings: 0,3-255
Default setting: 5 Parameter size: 2 [byte]
Parameter: 2. Automatic Temperature Value Reporting (Celsius)
Description: Unit 0.1 F:
0: OFF:
3-255: n *0.1F,automatically report to gateway when temperature variation greater than this value.
Available settings: 0,3-255
Default setting: 10 Parameter size: 2 [byte]
Parameter: 3. Automatic Humidity Value Reporting
Description: 0: OFF
1-99: Automatically report to gateway when humidity variation greater than this value.
Available settings: 0-99
Default setting: 6 Parameter size: 1 [byte]
Parameter: 12. Paremeter Menu No. E02: Power Failure Memory
Description: When power on again:
0:device will be in shutdown state (“OFF”);
1: device will be in working interface;
2: device will stay the last status before power failure.
Available settings: 0-2
Default setting: 1 Parameter size: 1 [byte]
Parameter: 13. Paremeter Menu No. E03: Backlight Brightness
Description: 1: dim, dim without key touch
2: Low brightness
3: Medium brightness
4: High brightness
5: Always on
Available settings: 1-5
Default setting: 2 Parameter size: 1 [byte]
Parameter: 14. Paremeter Menu No. E04: Beep
Description: 1: OFF2 Low Beep
3: Medium Beep
4: High Beep
5: Standard Beep
Available settings:
Default setting: 0 Parameter size: 1 [byte]