PROGRAMMING TIMER TIME
The TIMER function has to be active (jumper on 3, see Fig. 9) to programme time. Temporarily
remove the channel selection jumper if you do not want to activate the relays.
1) Press key 1 on the transmitter and hold it down (on an already functioning transmitter) then,
within 3 seconds, you must:
2) Press the receiver key and hold it down.
3) Release the transmitter key.
4) Release the receiver key after a time equivalent to the time you wish to programme (2.5 h max.)
The time is now memorised and will not change unless it is programmed again.
N.B. The receiver’s normal operation is inhibited while you are programming timer time (channels are
not active)
GB