be enabled in the receivers involved to increase their reception range. In this way, the receiver that received the
command via radio can retransmit it through the BusT4 cable to the destination receiver (in which the identica-
tion code of the transmitter that sent the command is memorised), so that the latter can execute the command.
This function is disabled by default. To enable (or disable) the repetition and/or reception of the code via BusT4,
programme the relevant receivers appropriately through the O-View and O-Box programmers.
4.6 - Blocking access (through password) to the receiver programming
This function activates in the receiver (with the O-Box / O-View programmer) a password consisting of maximum
10 characters, chosen by the installer. The function allows for protecting all the settings already effected in the
receiver; moreover, it also prevents any subsequent settings through key A of the receiver (Fig. 1) or through
the O-Box and O-View programmers, if the password is not known.
5
TECHNICAL SPECIFICATIONS
OXIBD
Product type Two-way receiver
Decoding OXIBD: “BD” / “O-code” / “FloR” / “TTS” / “Flo” / “Smilo”
OXIBD/A: “BD” / “O-code/A”
Input impedance 50 Ω
Reception frequency 433.92 MHz
Transmission frequency 433.92 MHz (only BD)
Outputs 4 (on “SM” plug-type connector)