EN
English – 13
TABLE 15 - Button LEDs on control unit
Led 1 Description
Off During normal operation, indicates “Automatic closure” not active.
On During normal operation, indicates “Automatic closure” active.
Flashes • Programming of functions in progress.
• If this flashes together with L2 this indicates that the device learning phase must be performed (see paragraph 4.4).
Quick flash After control unit start-up, it indicates a memory error regarding the devices connected.
At the same time, the “Bluebus” led emits
a diagnostic signal: 5 flashes - pause of 1 second - 5 flashes. In this case the learning phase for connected devices must be
performed (see paragraph 4.4).
Led 2 Description
Off During normal operation, indicates “Re-close after photo” not active.
On During normal operation, indicates “Re-close after photo” active.
Flashes • Programming of functions in progress.
• If this flashes together with L1 this indicates that the device learning phase must be performed (see paragraph 4.4).
Quick flash After control unit start-up, it indicates a memory error regarding the positions
. At the same time, the “Bluebus” led emits a diagnostic
signal: 5 flashes - pause of 1 second - 5 flashes. In this case the learning phase for the Opening and Closing positions must be
performed (see paragraph 4.5).
Led 3 Description
Off During normal operation, indicates “Re-close after photo” not active.
On During normal operation, indicates “Re-close after photo” active.
Flashes • Programming of functions in progress
• If this flashes together with L1 this indicates that the device learning phase must be performed (see paragraph 4.4).
Quick flash After control unit start-up, it indicates a memory error regarding the parameters and configurations
. At the same time, the “Bluebus” led
emits a diagnostic signal: 5 flashes - pause of 1 second - 5 flashes. In this case the memory must be deleted (see paragraph 8.1), and
also the learnt connected devices (see paragraph 4.4) and learnt Opening and Closing positions (see paragraph 4.5).
Led 4 Description
Off During normal operation, indicates “Stand-BY” not active.
On During normal operation, indicates “Stand-BY” active.
Flashes • Programming of functions in progress
• If this flashes together with L3 this indicates that the pole opening and closing learning phase must be performed (see paragraph 4.5).
Led 5 Description
Off During normal operation, indicates “Short deceleration” active.
On During normal operation, indicates “Long deceleration” active.
Flashes Programming of functions in progress.
Led 6 Description
Off During normal operation, indicates “Pre-flash” not active.
On During normal operation, indicates “Pre-flash” active.
Flashes Programming of functions in progress.
Led 7 Description
Off During normal operation, indicates “Current sensitivity control” not active.
On During normal operation, indicates “Current sensitivity control” active.
Flashes Programming of functions in progress.
TABLE 14 - Terminal LEDs on control unit
Bluebus LED Cause Solution
Off Fault Check for presence of the power supply; check that the
fuses are not blown; in this case, identify the cause of the
fault and then replace with versions with the same
specifications.
On Serious fault This indicates a serious fault; try switching off the control
unit for a few seconds; if the condition persists there is a
fault and the electronic board needs to be replaced.
1 flash per second All OK Normal operation of control unit
2 quick flashes Input status variation A variation to the status of the inputs SS, STOP, OPEN,
CLOSE, activation of the photocells, or when the radio
transmitter is used, is normal.
Series of flashes separated by a pause Various This is the same signal of 1 second as on the flashing light
(See table 15)
Led STOP Cause Solution
Off STOP input activation Check the device connected to the STOP input
On All OK Ingresso STOP attivo
S.S. LED Cause Solution
Off All OK S.S. Input not active
On S.S. input activation Normal if the device connected to the S.S. input is active
OPEN LED Cause Solution
Off All OK OPEN input not active
On OPEN input activation Normal if the device connected to the OPEN input is active
CLOSE LED Cause Solution
Off All OK CLOSE input not active
On CLOSE input activation Normal if the device connected to the CLOSE input is
active