12 – English
EN
V WU
L1L2L3
17
7.6 - STOP SAFETY EDGE Input
ThefunctionoftheSAFETYEDGEinputistocausetheimmediatestopofa
manoeuvre when in progress followed by a short reverse manoeuvre.
This input can be connected to devices such as optical sensitive edges (OSE)
orthosewith8.2kΩconstantresistanceoutput.
During the recognition phase, the control unit recognises the type of device
connected and causes a “STOP” whenever any variation in the recognised
status occurs.
Multiple devices, even of different types, can be connected to the STOP
SAFETYEDGEinputifappropriatelyorganised:
-NOdevices:connectthe8.2kΩresistorinparalleltothedevice;
-NCdevices:connectthe8.2kΩresistorinseriestothedevice;
- You can connect multiple NC devices “in series” with each other without
quantity limits;
-Iftherearemultipledevices,allmustbeconnected“incascade”withasingle
8.2kΩterminalresistance;
-YoucanalsocreateacombinationofNOandNCtypes,byplacingthetwo
contacts“inparallel”.Inthiscase,youneedtoplace a8.2kΩresistance“in
series”withtheNCcontact;thisalsomakesitpossibletoputthreedevices
together:NO,NCand8.2KΩ.
7.7 - Connecting a radio receiver
The control unit has an SM connector for connecting an SMXI, SMXIS, OXI,
OXIT or similar radio receiver (optional accessory, not supplied).
To connect the radio receiver, you must disconnect the mains power supply
from the control unit and insert the receiver as shown in Fig. 17.
Table2showstheactionsperformedbythecontrolunitaccordingtotheacti-
vated outputs or the commands sent by the radio receiver.
Note - For further information, refer to the instruction manual for the receiver.
TABLE 2
SMXI, SMXIS Receiver in “Mode 1 or 2”
output description
Output No. 1 Step-by-Step
OutputNo.2 Partial open; factory setting: it opens to halfway (this
may be changed during the position acquisition phase
or by using the Oview programmer)
OutputNo.3 Open
Output No. 4 Close
OXI, OXIT receiver programmed in “extended Mode 2”
command description
Command No. 1
Step-by-Step
CommandNo.2
Partial open; factory setting: it opens to halfway (this
may be changed during the position acquisition phase
or by using the Oview programmer)
CommandNo.3
Open
Command No. 4
Close
Command No. 5
Stop
CommandNo.6
Step-by-Step Condominium
Command No. 7
Step-by-Step High priority
CommandNo.8
Partialopen2
CommandNo.9
Partialopen3
Command No. 10
Open and Lock automation
Command No. 11
Close and Lock automation
CommandNo.12
Lock automation
CommandNo.13
Releaseautomation
Command No. 14
Timed Courtesy light
Command No. 15
CourtesylightON/OFF
7.8 - Initial startup and electrical connections test
Aftersupplyingpowertothecontrolunit,carryoutthefollowingchecks:
•VerifythatthegreenL2LED(closetotheDIPswitches)ashesregularly,with
afrequencyof1ashpersecond.
•Ifthe system is equipped withphotocells,checkthattheir LEDs ash cor-
rectly(RX);thetypeofashingisnotsignicantbecausethatdependsonother
factors.
•EnsurethattheredSAFETYLEDnearthekeyboardcableconnectorisper-
manentlyON(seeSafetyLEDDiagnosticstable,Paragraph10.2).
If any one of these tests fails to comply with requirements, you must discon-
nect the electrical power from the control unit and check the various electrical
connections made previously.
7.9 - Total deletion of the control unit memory
Youcandeleteallthedatastoredonthecontrolunitandrestoreittoitsoriginal
state with the default settings.
01. Setdipswitches1-2-3-
4 to ON = the red and
green ledsstartashing
quickly
ON
OFF
02. Press and hold the
STOPbuttonfor3sec.
until the green and red
leds remain lit
3”
ON
OFF
03. ReleasetheSTOP
button
04. At this point the control
unitperformsaRESET
= the red and green leds
startashingquickly
ON
OFF
RESET
05. Setdipswitches1-2-3-
4toOFF
ON
OFF
7.10 - Recognition of the safety devices and the Opening and
Closing positions
Afterperformingtheinitialstartup(paragraph7.8)andbe-
fore setting the gate Opening and Closing positions, you
must have the control unit run the recognition phase of
theconnectedsafetydevicesonthe“STOPSafetyEdge”
input.
CAUTION! - During the recognition phase, at least
one safety device must be connected to the control
unit.
OPEN
CLOSE
STOP
OPEN
STOP
CLOSE
01. Set dip switch 1 to ON =
-GreenLEDbeginstoash
rapidly
-RedLEDisOFF
ON
OFF
02. Press and hold the STOP button
until the red led comes on and
remainslit(afterabout3sec.)
3”
ON
OFF