7.6 - STOP SAFETY EDGE Input
ThefunctionoftheSAFETYEDGEinputistocausetheimmediatestopofa
manoeuvre when in progress followed by a short reverse manoeuvre.
This input can be connected to devices such as optical sensitive edges (OSE)
orthosewith8.2kΩconstantresistanceoutput.
During the recognition phase, the control unit recognises the type of device
connected and causes a “STOP” whenever any variation in the recognised
status occurs.
Multiple devices, even of different types, can be connected to the STOP
SAFETYEDGEinputifappropriatelyorganised:
-NOdevices:connectthe8.2kΩresistorinparalleltothedevice;
-NCdevices:connectthe8.2kΩresistorinseriestothedevice;
- You can connect multiple NC devices “in series” with each other without
quantity limits;
-Iftherearemultipledevices,allmustbeconnected“incascade”withasingle
8.2kΩterminalresistance;
-YoucanalsocreateacombinationofNOandNCtypes,byplacingthetwo
contacts“inparallel”.Inthiscase,youneedtoplace a8.2kΩresistance“in
series”withtheNCcontact;thisalsomakesitpossibletoputthreedevices
together:NO,NCand8.2KΩ.
7.7 - Connecting a radio receiver
The control unit has an SM connector for connecting an SMXI, SMXIS, OXI,
OXIT or similar radio receiver (optional accessory, not supplied).
To connect the radio receiver, you must disconnect the mains power supply
from the control unit and insert the receiver as shown in Fig. 17.
Table2showstheactionsperformedbythecontrolunitaccordingtotheacti-
vated outputs or the commands sent by the radio receiver.
Note - For further information, refer to the instruction manual for the receiver.
TABLE 2
SMXI, SMXIS Receiver in “Mode 1 or 2”
output description
Output No. 1 Step-by-Step
OutputNo.2 Partial open; factory setting: it opens to halfway (this
may be changed during the position acquisition phase
or by using the Oview programmer)
OutputNo.3 Open
Output No. 4 Close
OXI, OXIT receiver programmed in “extended Mode 2”
command description
Command No. 1
Step-by-Step
CommandNo.2
Partial open; factory setting: it opens to halfway (this
may be changed during the position acquisition phase
or by using the Oview programmer)
CommandNo.3
Open
Command No. 4
Close
Command No. 5
Stop
CommandNo.6
Step-by-Step Condominium
Command No. 7
Step-by-Step High priority
CommandNo.8
Partialopen2
CommandNo.9
Partialopen3
Command No. 10
Open and Lock automation
Command No. 11
Close and Lock automation
CommandNo.12
Lock automation
CommandNo.13
Releaseautomation
Command No. 14
Timed Courtesy light
Command No. 15
CourtesylightON/OFF
7.8 - Initial startup and electrical connections test
Aftersupplyingpowertothecontrolunit,carryoutthefollowingchecks:
•VerifythatthegreenL2LED(closetotheDIPswitches)ashesregularly,with
afrequencyof1ashpersecond.
•Ifthe system is equipped withphotocells,checkthattheir LEDs ash cor-
rectly(RX);thetypeofashingisnotsignicantbecausethatdependsonother
factors.
•EnsurethattheredSAFETYLEDnearthekeyboardcableconnectorisper-
manentlyON(seeSafetyLEDDiagnosticstable,Paragraph10.2).
If any one of these tests fails to comply with requirements, you must discon-
nect the electrical power from the control unit and check the various electrical
connections made previously.
7.9 - Total deletion of the control unit memory
Youcandeleteallthedatastoredonthecontrolunitandrestoreittoitsoriginal
state with the default settings.
01. Setdipswitches1-2-3-
4 to ON = the red and
green ledsstartashing
quickly
ON
OFF
02. Press and hold the
STOPbuttonfor3sec.
until the green and red
leds remain lit
3”
ON
OFF
03. ReleasetheSTOP
button
04. At this point the control
unitperformsaRESET
= the red and green leds
startashingquickly
ON
OFF
RESET
05. Setdipswitches1-2-3-
4toOFF
ON
OFF
7.10 - Recognition of the safety devices and the Opening and
Closing positions
Afterperformingtheinitialstartup(paragraph7.8)andbe-
fore setting the gate Opening and Closing positions, you
must have the control unit run the recognition phase of
theconnectedsafetydevicesonthe“STOPSafetyEdge”
input.
CAUTION! - During the recognition phase, at least
one safety device must be connected to the control
unit.
OPEN
STOP
CLOSE
01. Set dip switch 1 to ON =
-GreenLEDbeginstoash
rapidly
-RedLEDisOFF
ON
OFF
02. Press and hold the STOP button
until the red led comes on and
remainslit(afterabout3sec.)
3”
ON
OFF