2.2. Product specification
Nominal input voltage and frequency
(Notes 1, 2)
L / N = 115-127 V, 50/60 Hz
M / N / W = 220-240 V, 50/60 Hz
Minimum input voltage
(Note 3)
L / N = 85 V
M / W = 160 V
Maximum input voltage (Note 4)
L = 140 V
M / W = 264 V
N = 280 V
Maximum input overvoltage
L = 140 V (Note 6)
M = 300 V (Notes 5, 6)
N / W = 350 V (Notes 5, 6)
CF01Fxx L / CF01Fxx N = 2,5 A
CF02Fxx L = 4,0 A
CF01Fxx M / CF01Fxx W = 1,3 A
CF02Fxx M / CF02Fxx W = 2,0 A
Maximum input power (Note 7)
CF01F = 150 W
CF02F = 230W/240 W
Standby consumption (Note 8)
Frequency control version
- CF0xFx1/CF0xFx2 < 0,18 / 0,35 W
- CF0xFx3 < 0,10 / 0,19 W
Serial control version
- CF0xFx1/CF0xFx2 < 0,30 W / 0,45 W
- CF0xFx3 < 0,16 / 0,23 W
Drop-in control version < 0,35 W
Maximum inrush current (Note 9)
L = 195 A @ 25°C
M / W = 32 A @ 25°C
N = 90 A @ 25°C
Output electrical frequency range
(Notes 10, 11)
VES Compressors: 31,7 – 150 Hz
FMX Compressors: 43,3 – 160 Hz
FMS Compressors: 90,0 – 315 Hz
Motor speed range (Notes 10, 11)
VES Compressors: 950 – 4500 rpm
FMX Compressors: 1300 – 4800 rpm
FMS Compressors: 1800 – 6300 rpm
FMX Compressors: 1,80 A
VES, FMS Compressors: 2,17 A
Environmental humidity (Note 12)
10 % to 85 % (without condensation)
Storage temperature (Note 13)
Operational temperature
(Notes 13,14,15,16)