SI-Ethernet User Guide 91
Issue: 3
Safety
information
Introduction
Mechanical
installation
Electrical
installation
Getting started
Parameters
Key features
and Protocols
PC Tools
Applications
Security Diagnostics
Glossary of
terms
Index
Defines the event number to trigger in the given destination (slot) when a late synchronized frame
is received on the Rx3 link.
6.1.6 Menu 15 – Modbus
This parameter is used to enable or disable Modbus master and slave functionality.
This parameter is used to perform a warm reset of the Modbus protocol interface. When set and the
protocol has reset, the parameter will be reset to zero (Off).
S.11.062 Rx3 Late Sync Frame Event
Minimum
0
(Display: No Event)
Maximum
4
(Display: Event3)
Default
0
(Display: No Event)
Units None
Type 8 Bit User Save Update Rate Read on reset
Display Format None Decimal Places 0
Coding RW, Txt, BU
Value Text Description
0 No Event No event
1 Event Trigger module event
2 Event1 Trigger module event 1
3 Event2 Trigger module event 2
4 Event3 Trigger module event 3
This feature is not yet implemented.
S.15.001 Enable
Minimum
0
(Display: Off)
Maximum
1
(Display: On)
Default
1
(Display: On)
Units None
Type 1 Bit User Save Update Rate Background read
Display Format None Decimal Places 0
Coding RW, BU
S.15.002 Reset
Minimum 0
(Display: Off)
Maximum
1
(Display: On)
Default 0
(Display: Off)
Units None
Type 1 Bit Volatile Update Rate
Background read; written to 0
on initialization
Display Format None Decimal Places 0
Coding RW, NC