Do you have a question about the Nidek Medical ARK-760A and is the answer not in the manual?
Type | Auto Ref/Keratometer |
---|---|
Minimum Pupil Diameter | 2.0 mm |
Display | 5.7-inch color LCD |
Printer | Built-in thermal printer |
Power Supply | AC 100-240 V, 50/60 Hz |
Measurement Range (Keratometry) | 33.00 to 67.50 D |
Axis | 1° to 180° |
Measurement Mode | Auto / Manual |
Measurement Range (Cylinder) | 0 to ±10.00 D |
Pupil Diameter Measurement Range | 2.0 to 9.5 mm |
Flowchart for diagnosing issues and listing items to check for operational problems.
Troubleshooting steps for no display or abnormal display on the TV monitor.
Diagnosing and resolving 'Err' messages that appear after turning on the power.
Troubleshooting specific 'Err 1' indicating a sensor carry malfunction.
Diagnosing and resolving 'Err 2' related to the chart carry mechanism.
Troubleshooting steps for 'Err 3' indicating a problem with the rotator.
Resolving 'Err 4' which signifies a chart-related error.
Troubleshooting 'Err 5' (CL1) and 'Err 6' (CL2) errors for cylinder lens sensors.
Diagnosing and fixing 'Err 7' related to the line printer operation.
Troubleshooting 'Err 8' for issues with the serial printer.
Resolving 'Err 9' indicating a memory failure in the EEPROM.
Troubleshooting 'Err A' for memory failure in the RAM.
Diagnosing and resolving 'PD ERR' messages during measurements.
Troubleshooting the AR-600 shutter failing to open for early models.
Diagnosing why the raster is not visible or the TV monitor is not lit.
Troubleshooting the absence of an eye image on the TV monitor.
Resolving issues with unclear or missing characters/targets on the TV monitor.
Troubleshooting failure to switch between manual and auto-tracking modes.
Resolving inability to place the instrument in objective measurement mode.
Troubleshooting issues where parameter settings cannot be modified.
Diagnosing problems with changing the instrument's measuring mode.
Troubleshooting smooth movement problems of the measuring unit on a plane and vertically.
Resolving instability issues with the measuring unit.
Troubleshooting the absence of alignment light (AR-600) or Mire Ring (ARK-700).
Resolving issues with a blurry or unclear model eye image on the TV monitor.
Troubleshooting why the AR measurement process does not initiate.
Diagnosing and resolving 'Err' messages that occur during AR measurements.
Troubleshooting when the obtained SPH value is inaccurately shifted.
Resolving issues where the obtained CYL value is excessively high.
Troubleshooting the absence of a short beep when pressing the Start button.
Resolving issues with the IOL mode failing to activate.
Troubleshooting problems when the Cylinder mode cannot be switched.
Diagnosing why the instrument fails to recognize the patient's left and right eyes.
Troubleshooting inability to place the instrument in PD mode for measurement.
Resolving issues with an abnormal or incorrect PD measurement value.
Diagnosing and resolving 'Err' messages that occur during KM measurements.
Troubleshooting when the obtained KM value is abnormal or incorrect.
Resolving problems with the smooth up-and-down movement of the chin rest.
Troubleshooting why the chart is not visible in the measuring window.
Diagnosing why 'Err' does not appear even when the patient blinks during measurement.
Resolving issues where the auto-tracking function fails to operate.
Troubleshooting the auto-shot function not initiating or working correctly.
Diagnosing and resolving 'Err IF' messages indicating interface communication errors.
Troubleshooting issues where the printer fails to function or print.
Procedure for replacing the main control board (PC1) of the instrument.
Instructions for replacing the core measuring unit of the instrument.
Calibrating sensors by adjusting VR1 (S.GAIN) and VR2 (S.ZERO) on the PC6 board.
A comprehensive chart detailing error codes, their indications, contents, and details.