NIDEK
AR-600/ARK-700 SERIES
SERVICE MANUAL
FOR AR-600 ARK-700
AR-600A ARK-700A
AR-660A ARK-760A
MAR10*RTZ001C/E
Total Page: 164
2003. 12

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Nidek Medical ARK-700A and is the answer not in the manual?

Nidek Medical ARK-700A Specifications

General IconGeneral
DisplayLCD
PrinterBuilt-in thermal printer
TypeAuto Ref/Keratometer
Measurement Range (Sphere)-25D to +22D
Measurement Range (Keratometry)5D to 65D
Axis Range0° to 180°
Vertex Distance12 mm
Pupil Diameter Measurement Range2.0 to 8.0 mm
PD Measurement Range45 to 85mm
Corneal Curvature Radius5.0 to 10.0 mm
Measurement ModeAuto
Power SupplyAC100 to 240V, 50/60Hz

Summary

Caution

Troubleshooting

TV Monitor Display Issues

Troubleshooting for abnormal monitor display or no display.

"Err" Message Troubleshooting

Troubleshooting guide for "Err" message after power on.

AR Measurement Start Failure

Troubleshooting for AR measurement failing to start.

Measurement Value Shifts (SPH/CYL)

Troubleshooting for shifted SPH value in obtained measurements.

Instrument Recognition Failure (Left/Right)

Troubleshooting for instrument's failure to recognize left and right sides.

Auto-tracking and Auto-shot Function Failures

Troubleshooting for non-functional auto-tracking and auto-shot.

"Err IF" Interface Error Message

Troubleshooting for "Err IF" (Interface Error) message.

Checking Mains Supply Condition

Checking Continuity of Switches

Checking Electric Parts

Replacing Circuit Boards

Replacing PC1 (MAIN) Board

Procedure for replacing the PC1 (MAIN) circuit board.

Replacing Parts

Replacing the Measuring Unit

Procedure for replacing the measuring unit for various models.

Adjusting Each Part

Calibrating CCD Camera Lens Focus

Calibrating CCD camera lens focus for accurate measurements.

Positioning the Target

Procedure for positioning the target for calibration.

Sensor Calibration (PC6 Board)

Sensor calibration by adjusting VR1 and VR2 on the PC6 board.

Adjusting SPH Correction Range

Adjusting the SPH correction range for measurements.

KM Auto-Calibration (ARK-700 Series)

Performing KM auto-calibration for ARK-700 series.

Setting EEPROM DATA

Procedure for setting EEPROM data.

Setting Sensor Offset (SO)

Procedure for setting Sensor Offset (SO).

Tracking Auto-Calibration (Except AR-600/ARK-700)

Performing tracking auto-calibration for specific models.

Program for Adjustment

AR ADJUST Procedures

Procedures for AR adjustment modes.

Replacing ROM (Program)