4.7 Electrical Standards
Input ratings (controller)
Input supply voltage: 100 to 240 V AC (automatic switching)
Input supply voltage: 50/60 Hz
Current consumption: 5A to 2.5A
Supply voltage fluctuation: within ± 10%
Electric shock protection class: Class 1 (grounded connection type)
Installation category: Category 2
Power cord: Use only the power cord described below. Using the
wrong power cord could lead to fire or other dangerous
conditions.
Because this product belongs to electric shock
protection class 1, this product must be grounded.
In Japan:
Use only a PSE-marked detachable three-conductor
power cord set.
125 V AC, 7A minimum.
In a 100 V, 120 V region:
Use only a UL-certified detachable three-conductor
power cord set with a ground prong.
3-conductor grounding type SVT, No. 18 AWG, 3 m
long maximum, rated at 125 V AC minimum.
In a 220 V, 230 V, 240 V region:
Use only a EU/EN-certified three-conductor power
cord.
3-conductor grounding type H05VV-F, 3 m long
maximum, rated at 250 V AC minimum.
4.8 Applicable Electrical Safety Standards
In a 100 V, 120 V region:
This product meets FCC 15B Class A requirements.
This equipment has been tested and found to comply with the limits for a Class A digital
device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference when the equipment is operated in a
commercial environment. This equipment generates, uses, and can radiate radio
frequency energy and, if not installed and used in accordance with the instruction manual,
may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
This class A digital apparatus meets all requirements of the Canadian Interference-
Causing Equipment Regulations.
Cet appareil numérique de la Class A respecte toutes les exigences du Règlement sur le
matériel brouilleur du Canada.
In a 220 V, 230 V, 240 V region:
This product satisfies the EU’s low voltage directive.
This product satisfies the EU’s EMC directive.