ELECTRICAL SYSTEM
FORM NO. 56043088 / Advenger
/ BR 600S, 650S, 700S, 800S - 65
SPECIAL PROGRAM OPTIONS (CONTINUED)
Squeegee Raise-In-Reverse Time Period Adjustment:
FACTORY DEFAULT: 17 (4.4 SECONDS)
When backing up with the recovery system active, the control unit will automatically raise the squeegee just enough to prevent dragging on the
oor. The time that the squeegee is raised is adjustable from 1 to 4.8 seconds in .2 second increments. To adjust the distance the squeegee is
raised in reverse perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub pressure decrease and the vacuum switch.
3 While holding both switches turn the main power key switch to the on position.
4 Continue to hold both switches until the vacuum indicator is ashing yellow.
5 Release both switches. The status display will now indicate a number from 0 to 19 depending on the current time period. NOTE: If the decimal
point is not illuminated the display is indicating 0 – 9. If the decimal point is illuminated the display is indicating 10 – 19.
6 Pressing and releasing the vacuum switch will now select the time period. The level will increment from 0 to 19; 0 = 1 second, 1 = 1.2 seconds,
2 = 1.4 seconds, ... up to 19 = 4.8 seconds.
7 To save the new setting turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
Back-up Alarm Volume Control:
FACTORY DEFAULT: 0 (OFF)
The Advenger/BR 600, 650, 700 & 800 is equipped with an audible warning device which functions as a horn, a back-up alarm, and a forward
annunciator. The volume of the back-up alarm can be adjusted to one of ten settings. 1 is the minimum setting and 9 is the maximum setting, 0 is
off. To change the back-up alarm volume perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the horn switch.
3 While holding the horn switch turn the main power key switch to the on position.
4 Continue to hold the horn switch until the red battery status indicator is lit and the status display shows a number from 0 to 9 depending on the
current volume setting.
5 Release the horn switch.
6 Pressing and releasing the horn switch will now select the volume level. The level will increment from 0 to 9, 9 being the loudest. To hear the
back-up alarm volume select the reverse direction by pressing lightly on the throttle.
7 To save the new setting turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.
Forward Annunciator Volume Control:
FACTORY DEFAULT: 0 (OFF)
The Advenger/BR 600, 650, 700 & 800 is equipped with an audible warning device which functions as a horn, a back-up alarm, and a forward
annunciator. The volume of the forward annunciator can be adjusted to one of ten settings. 1 is the minimum setting and 9 is the maximum setting,
0 is off. To change the forward annunciator volume perform the following steps:
1 Turn the main power key switch to the off position.
2 Press and hold the scrub system off and the horn switch.
3 While holding both switches turn the main power key switch to the on position.
4 Continue to hold both switches until the green battery status indicator is lit and the status display shows a number from 0 to 9 depending on the
current volume setting.
5 Release the horn switch.
6 Pressing and releasing the horn switch will now select the volume level. The level will increment from 0 to 9, 9 being the loudest. To hear the
forward annunciator volume select the forward direction by pressing lightly on the throttle.
7 To save the new setting, turn the main power key switch to the off position.
8 The new setting will be saved and will remain in effect until it is changed again.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance Advenger 2600D and is the answer not in the manual?

Nilfisk-Advance Advenger 2600D Specifications

General IconGeneral
BrandNilfisk-Advance
ModelAdvenger 2600D
CategoryFloor Machine
LanguageEnglish

Related product manuals