VHT37EXP
02/2013
9
C397
US
Shaking the primary lter
Figure 9-10
Depending on the vacuumed dust quantity and if the pointer
of the vacuum gauge switches from the green zone (3, Fig. 9)
to the red zone (2, Fig. 9), turn the vacuum cleaner off and
shake the main lter using the knob (1, Fig. 10).
WARNING!
Stop the vacuum cleaner before shaking the lter.
Do not shake the lter while the vacuum cleaner is on,
as this could damage the lter itself.
Wait a few seconds before restarting the vacuum cleaner, to
allow the dust to settle. Replace the lter element if the pointer
still remains in the red zone (1, Fig. 9) even after the lter has
been shaken (consult the “Primary star lter replacement”
paragraph).
Emergency stopping
Turn the manual motor starter to the “0” position.
Emptying the container
WARNING!
Before proceeding with these operations, turn off the
vacuum cleaner and remove the plug from the power
socket.
Before emptying the container it is advisable to clean the lter
(see “Shaking the primary lter” paragraph).
Polyliner
An antistatic polyliner can be used to collect dust (see Fig. 11).
In this case, the vacuum cleaner must be equipped with
optional accessories [depressor (3) and grid (2), Fig. 11].
At the end of a cleaning session
Turn off the vacuum cleaner and remove the plug from
the socket.
Coil the power supply cord and store it on the hanger at
the center of the handle (Fig. 12). Empty the container as
described in the “Emptying the container” paragraph.
Clean the vacuum cleaner as described in the
“Maintenance, cleaning and decontamination” paragraph.
Wash the container with clean water if aggressive
substances have been vacuumed.
Store the vacuum cleaner in a dry place, out of reach of
unauthorized people.
[ NOTE ]
Let the vacuum cleaner run for at least 60 seconds before
turning it off.
Wait at least 5 minutes before turning the vacuum on again.
Failure to follow these instructions could cause premature
wear of motor / starter.
Maintenance, cleaning and
decontamination
WARNING!
The precautions described below must be taken
during all maintenance operations, including cleaning
and replacing the primary and HEPA lters.
WARNING!
The maintenance, cleaning and decontamination
operations must only be performed with the vacuum
cleaner turned off and the plug disconnected from the
power socket.
It is absolutely forbidden to perform maintenance with
the plug connected to the socket.
Danger of electric shock!
If the user is performing the maintenance operations, all
the suitable precautions should be taken. The suitable
precautions include decontamination, adequate ltered
ventilation of the exhaust air from the room in which
maintenance is performed, cleaning the maintenance
area and suitable personal protection.
WARNING!
This vacuum cleaner can be equipped with an
absolute (HEPA) lter for vacuuming dust hazardous
to one’s health. The procedures for servicing and
emptying the vacuum cleaner, including removing the
dust container, must only be performed by authorized
personnel wearing protective clothing. Do not use
without the complete lter system in place.
All parts of the vacuum cleaner must be considered
contaminated when they are removed from the
hazardous zone and appropriate actions must be taken
to prevent the dispersion of dust.
When maintenance or repair procedure are carried out,
all the contaminated elements that cannot be properly
cleaned must be eliminated.
These elements must be disposed of in sealed bags,
conform to applicable regulations and in accordance with
the local laws governing the disposal of such material.
This procedure must also be followed when the lters are
eliminated (primary and absolute lters).
Compartments that are not dust-tight must be opened
with suitable tools (screwdrivers, wrenches, etc.) and
thoroughly cleaned.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-Advance cfm VHT37EXP and is the answer not in the manual?

Nilfisk-Advance cfm VHT37EXP Specifications

General IconGeneral
BrandNilfisk-Advance
Modelcfm VHT37EXP
CategoryVacuum Cleaner
LanguageEnglish

Related product manuals