Fault Cause Remedy
When the cleaner is switched
on the motor buzzes without
starting.
The main voltage is too low
or there is a phase failure
(3 ph model).
The pump is blocked or
frozen.
Incorrect cross-section or
lenght of the extension lead.
Have the electrical
connections checked.
Pump needs service
(see part ”F”).
Use lead with correct cross
section and length.
The motor switches off.
The overload protection has
been activated due to
overheating or overloading
of the motor.
High pressure nozzle is
dirty.
Check that the main voltage
and the cleaner voltage are
the same.
Switch off the cleaner and
allow it to cool for at least
3 minutes.
Change the high pressure
nozzle.
Cleaner starts / stops by itself.
Leakage on high pressure
side.
Locate the leak and repair
it.
No detergents drawn in.
Injector is dirty or suction
hose is blocked.
Detergent container empty.
The cap on the nozzle is
not set at low pressure.
Clean.
Top up/change the
container.
Turn cap of the
FlexoPower nozzle towards
”CHEM” up to the stop.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nilfisk-ALTO POSEIDON 4 Series and is the answer not in the manual?

Nilfisk-ALTO POSEIDON 4 Series Specifications

General IconGeneral
BrandNilfisk-ALTO
ModelPOSEIDON 4 Series
CategoryPressure Washer
LanguageEnglish

Related product manuals